5 
 
2) Automatic switching by frequency command 
 
Frequency priority selection parameter f200 = 1 
Switch frequency command set with fmod and f207 automatically according to the frequency command 
entered. 
If the frequency set with fmod is above 1Hz: The frequency command set with fmod 
If the frequency set with fmod is 1Hz or less: The frequency command set with f207 
 
 
 
 
 
 
 
 
 