E6581611
K-27
11
PM motor parameters
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference

0900
Factory specific
coefficient 9A
- - - -
*3

0901
Factory specific
coefficient 9B
- - - -

0902
Factory specific
coefficient 9C
- - - -

0909
Factory specific
coefficient 9D
- - - -

0910 Step-out detection
current level
%
1/0.01 1-150 100 6.39

0911 Step-out detection
time
s 0.01/0.01 0.00: No detection
0.01-2.55
0.00

0912
q-axis inductance
mH 0.01/0.01
0.01-650.0 10.00
6.25.2
6.39

0913
d-axis inductance
mH 0.01/0.01
0.01-650.0 10.00

0914
Factory specific
coefficient 9E
- - - -
* 3

0915
Factory specific
coefficient 9L
- - - -

0916
Factory specific
coefficient 9F
- - - -

0917
Factory specific
coefficient 9G
- - - -

0918
Factory specific
coefficient 9H
- - - -

0919
Factory specific
coefficient 9I
- - - -

0920 Factory specific
coefficient 9J
- - - -

0930 Factory specific
coefficient 9K
- - - -
*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
Traverse parameters
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference

0980
Traverse selection
- 1/1 0: Disabled
1: Enabled
0
6.40

0981
Traverse
acceleration time
s 0.1/0.1 0.1-120.0
25.0

0982
Traverse
deceleration time
s 0.1/0.1 0.1-120.0
25.0

0983
Traverse step
% 0.1/0.1 0.0-25.0
10.0

0984
Traverse jump
step
% 0.1/0.1 0.0-50.0
10.0
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net