SETTINGS – AUTO CHANGEOVER
19
DEFINITION DEPENDENCIES FUNCTION
Pressing the Auto Changeover field in the “System Settings
Screen” will invoke the “Auto Changeover Screen” which will
allow a time choice from 5 minutes to 30 minutes for the auto
changeover functionality, adjustable in 5 minute increments.
Pressing the Defaults Button will load the default setting of
“30 MIN” (the user will still need to Save or Cancel this
setting). Pressing the Cancel Button will navigate back to
the “System Settings Screen”.
None This functionality sets up the minimum
time between switching from heat-to-
cool or from cool-to-heat demands
when operating in Auto Mode. The
timer begins when the Minimum OFF
Timer expires.