heat temperature range | 40° to 90°F (4.5° to 32°C) |
---|---|
cool temperature range | 50° to 99°F (10° to 37°C) |
operating ambient temperature | 0° to 120°F (-18° to 48.9°C) |
shipping temperature | -30° to 150°F (-34° to 66°C) |
operating relative humidity | 5% to 90% (non-condensing) |
heating voltage | 20-30 Vac |
---|---|
heating running current | 0.02-1.0 A |
heating powerpile voltage | 750 mV DC |
heating powerpile current | 100 mA DC |
cooling voltage | 20-30 Vac |
cooling running current | 0.02-1.0 A |
auxiliary heat voltage | 20-30 Vac |
auxiliary heat current | 0.02-1.0 A |
changeover voltage | 20-30 Vac |
changeover current | 0.02-0.6 A |
emergency heat voltage | 20-30 Vac |
emergency heat current | 0.02-1.0 A |
heat pump reset voltage | 20-30 Vac |
heat pump reset current | 0.02-0.6 A |
height | 4-9/16” (116 mm) |
---|---|
width | 6” (152 mm) |
depth | 1-3/8” (35 mm) |
Defines terminal letters for conventional and heat pump systems.
Wiring for 1 Heat/1 Cool conventional system with one transformer.
Wiring for 1 Heat/1 Cool conventional system with two transformers.
Wiring configurations for heat-only conventional systems.
Wiring configurations for cool-only conventional systems.
Wiring for 2 Heat/2 Cool conventional system with one transformer.
Wiring for 2 Heat/2 Cool conventional system with two transformers.
Select the type of HVAC system the thermostat controls.
Test cooling system operation, including compressor and fan.
Test heating system operation, including stages and fan.
Test emergency heating system operation.