Installation Guide
69-2268—03 10 570-219
M29127
Duringinstallersetup,presst
repeatedlyuntil“Test”appears.
Test
number
System
status
Press st to
select test
Press st to
change status
Press DONE to terminate testing.
Shadedareasbelowapplyonly to P340-1320.
1 Cooling system 0 Compressorandfanturnoff
1 Compressorandfanturnon
2 Secondstagecompressorturnson
2 Fan system 0 Fanturnsoff
1 Fanturnson
3 Heating system 0 Heatandfanturnoff
1 Heatturnson(fanonifFunction0170issetforheatpump,
orifFunction0180issetto“1”)**Seepage6
2 Second stage heat turns on
3 Third stage heat turns on
4 Emergency
heating system
0 Heatandfanturnoff
1 Heatandfanturnon
2 Secondstageheatturnson(Auxiliaryheat)]
System test System status
CAUTION: EQUIPMENT DAMAGE HAZARD. Compressorprotectionisbypassed
duringtesting.Topreventequipmentdamage,avoidcyclingthecompressorquickly.
Installer system test