SETTINGS – INDOOR EQUIPMENT TYPE
7
DEFINITION DEPENDENCIES FUNCTION
Pressing the Indoor Equip Type field in
the “System Settings Screen” will invoke
the “Indoor Equip Type Screen” which
allows for selection of the type of indoor
equipment being used. Options for the
indoor equipment type include
FURNACE and AIR HNDLR. Once the
correct indoor equipment type is
selected, pressing the Save Button will
save the selection into non-volatile
memory.
None INDOOR EQUIPMENT — An indoor equipment type
must be chosen so that an airflow source is
available to the system operation. The two types of
indoor equipment defined for operation are a
FURNACE and an AIR HANDLER (sometimes also
referred to as a FAN COIL). The indoor equipment
is not required to have a heat source present, which
is selectable with the Indoor Equipment Stages
setting. If control of a PACKAGE UNIT is desired
and the PACKAGE UNIT has a natural or propane
heating source installed, the FURNACE option
should be selected.
If the INDOOR EQUIPMENT type of FURNACE is
chosen and the OUTDOOR EQUIPMENT type of
HP is chosen, then the defined DUAL FUEL
thermostat operation will be used for heating.