Page #59 background image
59
GB
DEHUMIDIFIER
Humidity Sensor
Malfunction.
L1
Compressor
and fan motor
stops. This but-
ton is invalid.
Humidity sensor is
short-circuited.
Humidity sensor is
damaged.
Display board is dam-
aged.
Freon-lacking pro-
tection
F0
Compressor
stops. Fan mo-
tor keeps on
running.
Refrigerant is leaking.
System is blocked.
High-temperature
overload protec-
tion
Η3
Ambient operation con-
dition is bad.
The evaporator and
condenser are blocked
with lth.
The system is abnor-
mal.
ELECTRIC SCHEMATIC DIAGRAM
Note: The Electric schematic diagram are subject to change without prior
notice. Please refer to which one on the unit you purchased.
Model: TDE-16GSP21
PE
AP1
DISP
AP2
DISP
BN(BK)
BU(WH)
TUBE TEMP.
BU
POWER
L
N
AC-L
N
COMP
TEMP/HUM
CN5
YEGN(GN)
MAIN BOARD
DISPLAY
BOARD
COMP
PE
YEGN
C
2
COMP.
TUBE
RT1
WIFI
SENSOR
WIFI
HEALTH
MODULE
OPTIONAL
PE
YEGN
HUMIDITY
SENSOR
ST
RD
SWITCH
PROXIMITY
AP3
CARBON
BRUSH
CHARGED
PARTICLE
MODULE
MODULE
UV
FAN
M1
BN
RD
C2
CAP.
FAN
MOTOR