TUBE REPLACEMENT
Your Experience Two amplier’s conservative de-
sign maximizes life of the tubes. You can expect
thatyour300Band5U4Gtubeswilllastinexcessof
1000,whilethe6SN7preampliertubesshouldlast
approximately 2500 hrs. Lacking the accurate time
measurement, we strongly recommend replacing the
outputtubesat20-30monthsinterval(dependingon
yourlisteninghabits)andsignaltubesateveryother
powertubereplacement(every24-36months).This
willensurethatthe amplieralwaysperforms atits
best and tube failure will not overstress other parts.
Beforeyoustartreplacementyoushouldmakecer-
tain that the unit is turned off and disconnected from
the AC outlet and that the tubes have cooled down.
Allowsufcienttime,minimum30minutes,fortubes
tocooldownandinternalcapacitorstodischarge.Be-
fore inserting a new tube, inspect the tube for cracks
and physical damage. Make sure that the pins are
straight. If you need to straighten the pins, be very
careful as it may cause the glass envelope to break,
causing the tube to lose the vacuum and fail as soon
astheamplierispoweredon,possiblydamagingthe
amplieraswell.Also,makesuretoinspectthetube
sockets for cracks and pin inserts. Carefully align the
pins with the socket and gently insert the new tube.
Never force a tube into a socket.
Should you decide to buy replacement tubes from
Trafomatic Audio, rest assured that they were fully
tested before the shipment.
Only 300B power tubes can be used. Regarding
preamplier tubes, the 6SN7 tube can be replaced
with other 6SN7 tube type (like 6N8P Russian ,
6SN7GTetc.).Noothertypesoftubescanbeused
astheymaycausedamagetotheamplier,whichis
not covered by the warranty.
Wedonotrecommendfrequentchangesofthetubes,
as the sockets are sensitive mechanical parts and are
rated for relatively small number of insertions.
Servicing
Becauseofitscarefuldesignandhighmanufactur-
ingstandards,yourampliershouldnormallyrequire
only minimal service to maintain its high level of per-
formance.
CAUTION
Lethal voltages are present inside the amplier.
Do not remove the amplier’s bottom cover and
do not tamper with components inside the unit
even with the power turned off. Servicing should
be left only to authorized and trained personnel.