Page #1 background imageLoading...
Page #1 background image
SSAAFFEETTYYWWAARRNNIINNGG
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
June 2020
44TT--VV00--SSFF--11QQ--EENN
Variable Speed ComfortLink II
Heat Pumps and Air Conditioners
4TWV0024A1000C
4TWV0036A1000C
4TWV0048A1000C
4TWV0060A1000C
4TTV0024A1000C
4TTV0036B1000C
4TTV0048A1000C
4TTV0060A1000C
4TTV0061A1000C
Scan t o see h el p
videos on this
product
NNoottee:: “Graphics in this document are for representation
only. Actual model may differ in appearance.”
Service Facts
Question and Answer IconNeed help?

Do you have a question about the Trane Technologies ComfortLink II 4TTV0060A1000C and is the answer not in the manual?

Trane Technologies ComfortLink II 4TTV0060A1000C Specifications

General IconGeneral
Model4TTV0060A1000C
TypeAir Conditioner
SEER Rating16
RefrigerantR-410A
Compressor TypeScroll
Sound Level (dB)72
Voltage208/230
Phase1
Cooling Capacity (BTU)60, 000 BTU

Summary

Service Facts

Safety Section - Outdoor

Hazardous Voltage and Refrigerant Handling

Covers dangers of electrical shock and lockout/tagout procedures.

Hot Surface and Service Valve Safety

Highlights risks of hot surfaces and proper service valve operation.

Safety Section - Electrical Hazards

400 Volts Electrical Hazard

Details severe electrical risks and waiting periods for safe component access.

Subcooling Charging in Cooling

Charging Method for 55°F to 120°F OD Ambient

Describes the recommended subcooling charging procedure for specific ambient conditions.

Sequence of Operation

Sequence of Operation - Heat Pump Modes

Defrost Control (Heat Pump only)

Demand Defrost and Fault Identification

Explains how demand defrost is enabled and faults are identified via CDA.

Variable Speed Alert Codes - Control and Sensor Faults

Alert Codes for Control and Sensor Failures

Details error codes for control failures and various sensor faults.

Variable Speed Alert Codes - Pressure and Communication Faults

Alerts for Pressure, Ground, and Communication Issues

Lists alert codes related to pressure monitoring and communication errors.

Variable Speed Alert Codes - EEV and Charge Faults

Alerts for EEV Malfunctions and Low Charge

Details error codes for EEV faults and system low charge conditions.

Variable Speed Alert Codes - Protection and Limp Modes

Alerts for Protection and Limp Mode Operations

Lists error codes related to system protection and limp mode operations.

Variable Speed Alert Codes - Drive Current Failures

Alerts for Drive Current and Voltage Failures

Details alert codes associated with drive current and voltage issues.

Troubleshooting - Communication Loss

Communication Loss Diagnostic Flowchart

Step-by-step guide to diagnose and resolve communication loss issues.

Troubleshooting - Breaker Trip Procedure

Troubleshooting - Start Compressor

Troubleshooting - Run Drive Diagnostic Test

Troubleshooting - Electronic Expansion Valve (EEV)

Technician Configuration Menu

Technician Control Menu - Test Procedures

TECH CONTROL - Charge/Check Charge Modes

Pressure Curves - 4TWV0024A

Related product manuals