EasyManua.ls Logo

Trane 4TXCB003DS3HCA User Manual

Trane 4TXCB003DS3HCA
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Table of Contents
General ............................................................................... 1
Application Information ................................................ 1
Recommendation ............................................................. 2
Furnace in Upflow Position .......................................... 2
Furnace in Downflow Position ..................................... 2
Furnace in Horizontal Right Position ........................ 3
Furnace in Horizontal Left Position ........................... 4
Maximum Airflow Setting, CFM ................................... 5
Installing / Brazing Refrigerant Lines ....................... 5
Leak Check........................................................................ 6
Condensate Drain Piping .............................................. 6
Cleaning the Coil ............................................................. 6
Outline Drawings ............................................................ 7
Troubleshooting Indoor TXV / Cooling Mode ......... 10
Installer’s Guide
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service informa-
tion pack upon completion of work.
WARNING
!
WARNING (Medium/high pressure)
Contains Refrigerant!
System contains oil and refrigerant under high pressure.
Recover refrigerant to relieve pressure before opening the
system. See unit nameplate for refrigerant type. Do not
use non-approved refrigerants, refrigerant substitutes, or
refrigerant additives.
Failure to follow proper procedures or the use of non-
approved refrigerants, substitutes, or refrigerant additives
could result in death, serious injury, or equipment damage.
A341869P33
IMPORTANT: Review your installation requirements. Check
the table on the outline drawings and note all dimensions
for your coil before beginning the installation.
Figure 1
18-AD35D1-2D-EN
Cased Aluminum "Convertible" Coils
Models:
4TXCA002DS3HCA
4TXCA032DS3HCA
4TXCB003DS3HCA
4TXCB004DS3HCA
4TXCB006DS3HCA
4TXCC005DS3HCA
4TXCC007DS3HCA
4TXCD008DS3HCA
4TXCC009DS3HCA
4TXCD010DS3HCA
NOTE:
OPTIONAL DOWNFLOW GASKET INSTALLATION: For
unusually humid applications that expect prolonged
operation above 70% RH, it is recommended to use the
BAYGSKT001A0 gasket kit to prevent water from forming
on the bottom of the drain pan and dripping into the sup-
ply ductwork.
WARNING
!
This product can expose you to chemicals including lead, which
are known to the State of California to case cancer and birth defects
or other reproductive harm. For more information go to www.
P65Warnings.ca.gov
A. GENERAL
These coils are designed for use in combination with a heat pump
or cooling outdoor section using R-410A REFRIGERANT.
The 4TXC equipment has been evaluated in accordance with
the Code of Federal Regulations, Chapter XX, Part 3280 or the
equivalent. “Suitable for Mobile Home use” The height of the
Furnace, Coil and discharge duct work must be 7 ft. or less.
Inspect the coil for shipping damage. Notify the transporta-
tion company immediately if the coil is damaged.
B. APPLICATION INFORMATION
1. FURNACE AND COIL
The coil MUST BE installed downstream (in the outlet air)
of the furnace.
2. INDOOR UNIT AIRFLOW
Indoor unit must provide the required airflow for the heat
pump or cooling combinations approved for these coils.
Question and Answer IconNeed help?

Do you have a question about the Trane 4TXCB003DS3HCA and is the answer not in the manual?

Trane 4TXCB003DS3HCA Specifications

General IconGeneral
BrandTrane
Model4TXCB003DS3HCA
CategoryFurnace Accessories
LanguageEnglish

Summary

Furnace in Upflow Position

Upflow Coil Conversion

Optional removal of coil components to maximize airflow efficiency.

Upflow Gas Furnace Installation

Steps for connecting the coil case to the furnace and sealing for air leaks.

Furnace in Downflow Position

Downflow Coil Conversion

Optional removal of coil components to maximize airflow efficiency.

Optional Downflow Gasket Installation

Using gasket kit to prevent water formation on the drain pan.

Downflow Gas Furnace Installation

Steps for installing the coil case on the furnace supply air plenum.

Furnace in Horizontal Right Position

Horizontal Right Coil Conversion

Optional removal of coil components to maximize airflow efficiency.

Furnace in Horizontal Left Position

Horizontal Left Coil Conversion

Optional removal of coil components to maximize airflow efficiency.

Horizontal Left Installation Details

Connecting furnace and coil using alignment brackets and splash guard.

Maximum Airflow Settings

Installing and Brazing Refrigerant Lines

Refrigerant Line Installation and Brazing

Steps for running, bending, securing, and brazing refrigerant lines, including TXV protection.

Leak Check Procedure

Condensate Drain Piping

Condensate Drain Piping Installation

Instructions for clearing drain hole and connecting primary/secondary drain lines.

Cleaning the Coil

Coil Cleaning Procedure

Steps for cleaning the inside and outside of the coil with panels removed.

Troubleshooting Indoor TXV / Cooling Mode