EasyManua.ls Logo

Trane 4TXCB004DS3HCA User Manual

Trane 4TXCB004DS3HCA
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Table of Contents
General ............................................................................... 1
Application Information ................................................ 1
Recommendation ............................................................. 2
Furnace in Upflow Position .......................................... 2
Furnace in Downflow Position ..................................... 2
Furnace in Horizontal Right Position ........................ 3
Furnace in Horizontal Left Position ........................... 4
Maximum Airflow Setting, CFM ................................... 5
Installing / Brazing Refrigerant Lines ....................... 5
Leak Check........................................................................ 6
Condensate Drain Piping .............................................. 6
Cleaning the Coil ............................................................. 6
Outline Drawings ............................................................ 7
Troubleshooting Indoor TXV / Cooling Mode ......... 10
Installer’s Guide
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service informa-
tion pack upon completion of work.
WARNING
!
WARNING (Medium/high pressure)
Contains Refrigerant!
System contains oil and refrigerant under high pressure.
Recover refrigerant to relieve pressure before opening the
system. See unit nameplate for refrigerant type. Do not
use non-approved refrigerants, refrigerant substitutes, or
refrigerant additives.
Failure to follow proper procedures or the use of non-
approved refrigerants, substitutes, or refrigerant additives
could result in death, serious injury, or equipment damage.
A341869P33
IMPORTANT: Review your installation requirements. Check
the table on the outline drawings and note all dimensions
for your coil before beginning the installation.
Figure 1
18-AD35D1-2D-EN
Cased Aluminum "Convertible" Coils
Models:
4TXCA002DS3HCA
4TXCA032DS3HCA
4TXCB003DS3HCA
4TXCB004DS3HCA
4TXCB006DS3HCA
4TXCC005DS3HCA
4TXCC007DS3HCA
4TXCD008DS3HCA
4TXCC009DS3HCA
4TXCD010DS3HCA
NOTE:
OPTIONAL DOWNFLOW GASKET INSTALLATION: For
unusually humid applications that expect prolonged
operation above 70% RH, it is recommended to use the
BAYGSKT001A0 gasket kit to prevent water from forming
on the bottom of the drain pan and dripping into the sup-
ply ductwork.
WARNING
!
This product can expose you to chemicals including lead, which
are known to the State of California to case cancer and birth defects
or other reproductive harm. For more information go to www.
P65Warnings.ca.gov
A. GENERAL
These coils are designed for use in combination with a heat pump
or cooling outdoor section using R-410A REFRIGERANT.
The 4TXC equipment has been evaluated in accordance with
the Code of Federal Regulations, Chapter XX, Part 3280 or the
equivalent. “Suitable for Mobile Home use” The height of the
Furnace, Coil and discharge duct work must be 7 ft. or less.
Inspect the coil for shipping damage. Notify the transporta-
tion company immediately if the coil is damaged.
B. APPLICATION INFORMATION
1. FURNACE AND COIL
The coil MUST BE installed downstream (in the outlet air)
of the furnace.
2. INDOOR UNIT AIRFLOW
Indoor unit must provide the required airflow for the heat
pump or cooling combinations approved for these coils.
Question and Answer IconNeed help?

Do you have a question about the Trane 4TXCB004DS3HCA and is the answer not in the manual?

Trane 4TXCB004DS3HCA Specifications

General IconGeneral
BrandTrane
Model4TXCB004DS3HCA
CategoryFurnace Accessories
LanguageEnglish

Summary

General Information and Safety Precautions

General Coil Use and System Compatibility

Explains coil usage with heat pumps/cooling, CFR compliance, and mobile home suitability.

Furnace and Coil Installation Requirements

Specifies coil installation downstream of furnace and required indoor unit airflow.

Safety Warnings for Refrigerant Handling

Details high pressure, refrigerant recovery, and use of approved refrigerants.

California Proposition 65 Warning

Warns about lead exposure and potential health effects.

Optional Downflow Gasket Installation

Recommends a gasket kit for humid applications to prevent water formation.

Furnace Installation Configurations

Upflow Furnace Coil Conversion and Installation

Details optional component removal and connection for upflow furnace.

Downflow Furnace Coil Conversion and Installation

Details optional component removal, gasket installation, and connection for downflow furnace.

Horizontal Furnace Installation

Horizontal Right Furnace Coil Conversion and Installation

Details optional component removal and connection for horizontal right furnace.

Horizontal Left Furnace Coil Conversion and Installation

Details component removal, bracket use, and splash guard for horizontal left furnace.

Refrigerant Line Installation and Leak Check

Installing and Brazing Refrigerant Lines

Steps for routing, bending, securing, and brazing refrigerant lines, including TXV protection.

Leak Check Procedures

Steps for pressurizing, leak checking with soap bubbles, and repairing leaks.

Coil Maintenance and Drainage

Condensate Drain Piping

Details drain hole clearing, primary drain line insulation, and secondary drain line connection.

Cleaning the Coil

Instructions for cleaning the inside and outside of the coil using brush and vacuum.

Dimensional Data and Outline Drawings

Outline Drawing and Model Dimensions - Figure A

Provides outline drawing and dimensions for specific coil models (4TXCA/4TXCC/4TXCB).

Outline Drawing and Model Dimensions - Figure B

Provides outline drawing and dimensions for specific coil models (4TXCB003DS3).

Outline Drawing and Model Dimensions - Figure C

Provides outline drawing and dimensions for specific coil models (4TXCD008DS3/4TXCD010DS3).

Troubleshooting Indoor TXV / Cooling Mode