28
A5HL5-SF-1A-EN
Table 16. 4.0 Ton Heating
Sound Pressure Level dB(A) per ARI 275 (Max Cooling)
# Reflective Surfaces 3’ From Property Line 5’ From Property Line 7’ From Property Line
0 66 61
1 69
(a)
64
2 72 67 64
(a)
Lab tested as per the illustration shown above
Table 17. 4.0 Ton Cooling
Sound Pressure Level dB(A) per ARI 275 (Max Cooling)
# Reflective Surfaces 3’ From Property Line 5’ From Property Line 7’ From Property Line
0 63 58
1 66
(a)
61
2 69 64 61
(a)
Lab tested as per the illustration shown above
Table 18. 5.0 Ton Heating
Sound Pressure Level dB(A) per ARI 275 (Max Cooling)
# Reflective Surfaces 3’ From Property Line 5’ From Property Line 7’ From Property Line
0 66 61
1 69
(a)
64
2 72 67 64
(a)
Lab tested as per the illustration shown above
Table 19. 5.0 Ton Cooling
Sound Pressure Level dB(A) per ARI 275 (Max Cooling)
# Reflective Surfaces 3’ From Property Line 5’ From Property Line 7’ From Property Line
0 63 58
1 66
(a)
61
2 69 64 61
(a)
Lab tested as per the illustration shown above
Noise-With Barrier
Table 20. 2.0 Ton Heating
Sound Pressure Level dB(A) per ARI 275 (Max Cooling)
# Reflective Surfaces 6’ From Barrier 11’ From Barrier 16’ From Barrier
Normal Within 3m of the reflector 54 49 45.5
Low
Within 3m of the reflector
43 38 34.5
SSoouunndd PPrreessssuurree LLeevveell