EasyManua.ls Logo

Trane A5HL5060A1000A - Sound Pressure Level

Trane A5HL5060A1000A
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A5HL5-SF-1A-EN
27
Sound Pressure Level
Reflective Surface
(Back wall)
Outdoor Unit
3’ ft
3’ ft
Table 12. 2.0 Ton Heating
Sound Pressure Level dB(A) per ARI 275 (Max Heating)
# Reflective Surfaces 3’ From Property Line 5’ From Property Line 7’ From Property Line
0 60 55
1 63
(a)
58
2 66 61 58
(a)
Lab tested as per the illustration shown above
Table 13. 2.0 Ton Cooling
Sound Pressure Level dB(A) per ARI 275 (Max Cooling)
# Reflective Surfaces 3’ From Property Line 5’ From Property Line 7’ From Property Line
0 57 52
1 60
(a)
55
2 63 58 55
(a)
Lab tested as per the illustration shown above
Table 14. 3.0 Ton Heating
Sound Pressure Level dB(A) per ARI 275 (Max Cooling)
# Reflective Surfaces 3’ From Property Line 5’ From Property Line 7’ From Property Line
0 65.5 60.5
1 68.5
(a)
63.5
2 71.5 66.5 6.35
(a)
Lab tested as per the illustration shown above
Table 15. 3.0 Ton Cooling
Sound Pressure Level dB(A) per ARI 275 (Max Cooling)
# Reflective Surfaces 3’ From Property Line 5’ From Property Line 7’ From Property Line
0 61 56
1 64
(a)
59
2 67 62 59
(a)
Lab tested as per the illustration shown above

Related product manuals