A5HL5-SF-1A-EN
29
Table 21. 2.0 Ton Cooling
Sound Pressure Level dB(A) per ARI 275 (Max Cooling)
# Reflective Surfaces 6’ From Barrier 11’ From Barrier 16’ From Barrier
Normal Within 3m of the reflector 52 47 43.5
Low
Within 3m of the reflector
42 37 33.5
Table 22. 3.0 Ton Heating
Sound Pressure Level dB(A) per ARI 275 (Max Cooling)
# Reflective Surfaces 15 ’From Barrier 20’ From Barrier 25’ From Barrier
Normal Within 3m of the reflector 45 42.5 40.5
Low
Within 3m of the reflector
45 42.5 40.5
Table 23. 3.0 Ton Cooling
Sound Pressure Level dB(A) per ARI 275 (Max Cooling)
# Reflective Surfaces 15’ From Barrier 20’ From Barrier 25’ From Barrier
Normal Within 3m of the reflector
40 37.5 35.5
Low
Within 3m of the reflector
40 37.5 35.5
Table 24. 4.0 Ton Heating
Sound Pressure Level dB(A) per ARI 275 (Max Cooling)
# Reflective Surfaces 15 ’From Barrier 20’ From Barrier 25’ From Barrier
Normal Within 3m of the reflector
55 52.5 50.5
Low
Within 3m of the reflector
45 42.5 40.5
Table 25. 4.0 Ton Cooling
Sound Pressure Level dB(A) per ARI 275 (Max Cooling)
# Reflective Surfaces 15’ From Barrier 20’ From Barrier 25’ From Barrier
Normal Within 3m of the reflector
50 47.5 45.5
Low
Within 3m of the reflector
41 38.5 36.5
Table 26. 5.0 Ton Heating
Sound Pressure Level dB(A) per ARI 275 (Max Cooling)
# Reflective Surfaces 15 ’From Barrier 20’ From Barrier 25’ From Barrier
Normal Within 3m of the reflector
55 52.5 50.5
Low Within 3m of the reflector 45 42.5 40.5
Table 27. 5.0 Ton Cooling
Sound Pressure Level dB(A) per ARI 275 (Max Cooling)
# Reflective Surfaces 15’ From Barrier 20’ From Barrier 25’ From Barrier
Normal Within 3m of the reflector
51 48.5 46.5
Low Within 3m of the reflector 41 38.5 36.5
SSoouunndd PPrreessssuurree LLeevveell