88-A5PA3001-1A-EN
9
Product Specification
MODEL A5PA3024 A5PA3030 A5PA3036 A5PA3042 A5PA3048 A5PA3060
RATED Volts/PH/Hz 208–230/1/60
Performance Cooling BTUH
(a)
24000 28400 36800 40000 47500 58500
Indoor Airflow (CFM)
820 920 1190 1500 1670 1700
Power Input (KW)
LOCATED ON UNIT NAMEPLATE
EER2/SEER2 (BTU/Watt-Hr.)
(b)
10.6/13.4
Sound Power Rating [dB(A)]
(c)
66.6 70 69.3 74.6 72.5 73.1
POWER CONN. — V/Ph/Hz 208–230/1/60
Min. Brch. Cir. Ampacity
(d)
LOCATED ON UNIT NAMEPLATE
Fuse Size — Max. (amps)
25 30 40 40 50 60
Fuse Size — Recmd. (amps)
25 30 40 40 50 60
COMPRESSOR SCROLL
Volts/Ph/Hz 208–230/1/60
R.L. Amps — L.R. Amps
LOCATED ON UNIT NAMEPLATE
OUTDOOR COIL — TYPE SPINE-FIN
Rows/F.P.I 2 / 24
Face Area (sq. ft.)
13.32 13.32 15.49 15.63 20.54 22.99
Tube Size (in.)
3/8
INDOOR COIL — TYPE MCHE RTPF
Rows/F.P.I 2 / 16 4 / 15
Face Area (sq. ft.)
2.7 3.9 3.9 5.0
Tube Size (in.)
0.81 0.81 1.00 0.81 0.81 0.38
Refrigeration Control
EXPANSION VALVE
Drain Conn. Size (in.)
3/4 FEMALE NPT
OUTDOOR FAN — TYPE PROPELLER
DIA. (IN.)
23.4 28.3
DRIVE/NO. SPEEDS DIRECT / 1
CFM @ 0.0 in. w.g
(e)
2350 2800 3080 3400 3400 4800
Motor — HP/R.P.M 1/12 /825 1/6 /825 1/5 / 825 1/4 / 825 1/4 / 825 1/3 / 825
Volts/Ph/Hz 208–230/1/60
F.L. Amps/L.R Amps
LOCATED ON UNIT NAMEPLATE
INDOOR FAN — TYPE
CONSTANT TORQUE ECM
Dia. x Width (in.)
10.62 X 10.62 11.87 X 10.62
Drive/No. Speeds
DIRECT / 4
CFM @ 0.0 in. w.g
(f)
SEE FAN PERFORMANCE TABLE
Motor — HP / R.P.M. 1/3 / 1050 1/2 / 1050 3/4 / 1050 1 / 1050
Volts/Ph/Hz 208–230/1/60
F.L. Amps
LOCATED ON UNIT NAMEPLATE
FILTER / FURNISHED
NO
Type Recommended
THROWAWAY
Recmd. Face Area (sq. ft)
(g)
4 5.3
REFRIGERANT R-454B
Charge (lbs.)
LOCATED ON UNIT NAMEPLATE
CHARGING SPECIFICATIONS
Subcooling
12˚ F 10˚ F 12˚ F 12˚ F 10˚ F 13˚ F
(a)
Rated in accordance with AHRI Standard 210/240.
(b)
Rated in accordance with D.O.E. test procedure.
(c)
Sound Power values are not adjusted for AHRI 270–95 tonal corrections.
(d)
Calculated in accordance with currently prevailing Nat’l Electrical Code.
(e)
Standard Air — Dry Coil — Outdoor.
(f)
Standard Air — Dry Coil — Indoor
(g)
Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per
manufacturer’s recommendation with a clean resistance of 0.05” W.C.
IInnttrroodduuccttiioonn,, UUnniitt IInnssppeeccttiioonn aanndd SSppeecciiffiiccaattiioonn