EasyManua.ls Logo

Trane A801X026AM2SC - Product Specifications; Model Specifications (Part 2)

Trane A801X026AM2SC
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
A801X-SVX001-1A-EN
MODEL
A801X080BM4SC
(a)
A801X080CM5SC
(a)
A801X100CM5SC
(a)
A801X120DM5SC
(a)
Type
Upflow / Horizontal /
Downflow
Upflow / Horizontal /
Downflow
Upflow / Horizontal /
Downflow
Upflow / Horizontal /
Downflow
RATINGS
(b)
Input BTUH 80,000 80,000 100,000 120,000
Capacity BTUH (ICS)
(c)
65,100 64,700 80,700 98,000
Temp. Rise (Min. - Max.) °F
30 - 60 30 - 60 30 - 60 35 - 65
AFUE - Rating
(c)
80 80 80 80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F 55°F - 80°F 55°F - 80°F 55°F - 80°F
BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT
Diameter - Width (in.)
11 X 8 11 X 11 11 X 11 11 X 11
No. Used 1 1 1 1
Speeds (No.)
(d)
CTM - 9 CTM - 9 CTM - 9 CTM - 9
CFM vs. in. w.g.
See Fan Performance
Table
See Fan Performance
Table
See Fan Performance
Table
See Fan Performance
Table
Motor HP
3/4
1
3/4
1
R.P.M. 1050 1050 1050 1050
Volts / Ph / Hz 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
FLA 9.2 10.9 10.9 10.9
COMBUSTION FAN - Type
PSC PSC PSC PSC
Drive - No. Speeds
Direct - 1 Direct - 1 Direct - 1 Direct - 1
Motor RPM 3300 3300 3300 3300
Volts/Ph/Hz 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
FLA 0.29 0.30 0.33 0.33
Inducer Orifice 1.75 1.80 2.50 2.15
FILTER - Furnished? No No No No
Type Recommended High Velocity High Velocity High Velocity High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in. 1 - 20 X 25 - 1 in. 1 - 20 X 25 - 1 in. 1 - 24 X 25 - 1 in.
VENT PIPE DIAMETER - Min. (in.)
4 Round 4 Round 4 Round 4 Round
HEAT EXCHANGER - Type
Aluminized Steel Aluminized Steel Aluminized Steel Aluminized Steel
Gauge (Fired)
20 - 19 20 - 19 20 - 19 20 - 19
ORIFICES - Main
Nat. Gas Qty. - Drill Size
4 - 45 4 - 45 5 - 45 6 - 45
L.P. Gas Qty. - Drill Size
4 - 56 4 - 56 5 - 56 6 - 56
GAS VALVE
Redundant - Single
Stage
Redundant - Single
Stage
Redundant - Single
Stage
Redundant - Single
Stage
PILOT SAFETY DEVICE - Type 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter
BURNERS - QTY
4 4 5 6
POWER CONN. - V/Ph/HZ
(e)
120 / 1 / 60 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
Ampacity (Amps)
12.0 14.1 14.1 14.1
Max. Overcurrent Protection (Amps)
15 15 15 15
PIPE CONN. SIZE (IN.)
1/2 1/2 1/2 1/2
(a)
Central Furnace heating designs are certified to ANSI Z21.47 - latest edition.
(b)
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 10,000 feet for elevations above 2,000 feet above sea level.
(c)
Based on U.S. government standard tests
(d)
9 Speed constant torque ECM Blower Motor.
(e)
The above wiring specifications are in accordance with National Electric Code, however, installations must comply with local codes.
PPrroodduucctt SSppeecciiffiiccaattiioonnss