A801X-SF-1C-EN
9
MODEL A801X080CM5SAC A801X100CM5SAC A801X120DM5SAC
TYPE
Upflow / Horizontal /
Downflow
Upflow / Horizontal /
Downflow
Upflow / Horizontal /
Downflow
RATINGS
(a)
Input BTUH 80,000 100,000 120,000
Capacity BTUH (ICS)
(b) (c)
65,400 81,800 95,700
Temp. Rise (Min.-Max.)
30 - 60 30 - 60 30 - 60
AFUE (%)
(c)
80 80 80
Return Air Temp. (Min. - Max.)
55°F - 80°F 55°F - 80°F 55°F - 80°F
BLOWER DRIVE DIRECT DIRECT DIRECT
Diameter — Width (In.)
11 X 11 11 X 11 11 X 11
No. Used 1 1 1
Speeds (No.)
(d)
9 9 9
CFM vs. in. w.g.
See Fan Performance
Table
See Fan Performance
Table
See Fan Performance
Table
Motor HP 1 1 1
RPM 1075 1075 1075
Volts/Ph/Hz 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
FLA 10.9 10.9 10.9
COMBUSTION FAN — Type Centrifugal Centrifugal Centrifugal
Drive — No. Speeds
Direct - 1 Direct - 1 Direct - 1
Motor HP — RPM 3300 3300 3300
Volts/Ph/Hz 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
FLA 0.30 0.30 0.34
FILTER — Furnished? No No No
Type recommended High Velocity High Velocity High Velocity
High Vel. (No.-Size-Thk.)
1 — 20x25 — 1 in. 1 — 20x25 — 1 in. 1 — 24x25 — 1 in.
VENT PIPE DIAMETER — Min (in.)
(e)
4 Round 4 Round 4 Round
HEAT EXCHANGER — Type
Aluminized Steel Aluminized Steel Aluminized Steel
Gauge (Fired)
20 20 20
ORIFICES — Main
Nat. Gas Qty. — Drill Size
4 - 45 5 - 45 6 - 45
GAS VALVE
Redundant - Single Stage Redundant - Single Stage Redundant - Single Stage
PILOT SAFETY DEVICE
Type 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter
BURNERS — QTY
4 5 6
POWER CONN. — V/Ph/Hz
(f)
120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
Ampacity (Amps)
14.1 14.1 14.1
Max. Overcurrent Protection (Amps)
15 15 15
PIPE CONN. SIZE (in.)
1/2 1/2 1/2
(a)
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
(b)
Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 — latest edition.
(c)
Based on U.S. government standard tests.
(d)
9 Speed constant torque ECM blower motor.
(e)
Refer to the Installer's Guide.
(f)
The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
PPrroodduucctt SSppeecciiffiiccaattiioonnss