EasyManua.ls Logo

Trane ACONT900AC43UA - Control Board; Airflow (Lower than Expected)

Trane ACONT900AC43UA
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R - C 23
Reference Materials
Control Board
• 3-Stage Furnace (*UH3/*DH3)
- CNT04829
• LAST 4 FAULTS (User Interface)
- Add position identifier
Airflow (Lower Than Expected)
• 3 Stage A/TUH3 Furnaces
• Heads Up #905 sent via email 6/29/09
• Date codes affected 9061 – 9283
- Coincided with conversion to 16x motor
software
MOT13225
MOT13226
MOT13227
- 4 coefficient PM installed in 3 stage
product
- 5 coefficient PM installed in 80% comm
product
No airflow problems with 80%
furnaces
• 4 coefficient combined with 16x software results in
low airflow
• 5 coefficient PM’s developed for manufacturing
- Date code corrections implemented 9284
• FURN-SVB36A-EN
- 8/24/09 Revision to Bulletin
(Originally 7/24/09)
- All 3-Stage Furnaces (Upflow & Downflow)
Personality Module replacement
to resolve low airflow issue
Date range of units affected 9061
to 9283
16 Seer Update
Control Board Point Release
• CNT04880 to CNT06042
- 2-5 ton 16 SEER-COMSYS models only
- Defrost Control enhancements
Start Date (November 9th, 2009)
FW46
Summary of Issue - 16 Seer COMSYS
16 SEER Update - Control Board Point Release
• CNT06042
- Backward compatible for all COMSYS 16
SEER
- Software change for Defrost function only
- New models (9465****F and later):
Revert to pre-COMSYS termination
temperatures
Eliminate Fault B timed-defrost
• PM – Specialty Personality Module
- High Termination requirements
- Sales Order with New Equipment purchase
BAYHITEMP02A
(4A6H6024C1 & 4TWX6024C1)
BAYHITEMP03A
(4A6H6036C1 & 4TWX6036C1)
BAYHITEMP04A
(4A6H6048C1 & 4TWX6048C1)
BAYHITEMP05A
(4A6H6060C1 & 4TWX6060C1)
• Installer Guide 18-HH21D1-1
- High Temperature Defrost Termination
Personality Module

Table of Contents