EasyManuals Logo

Trane ADH1B065A9421A User Manual

Trane ADH1B065A9421A
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
18-CD29D1-11 39
Installer’s Guide
TABLE 21
INTEGRATED FURNACE CONTROL ERROR FLASH CODES
Flashing Slow --- Normal - No call for Heat
Flashing Fast --- Normal - Call for Heat
Continuous ON --- Replace IFC
Continuous OFF --- Check Power
2 Flashes --- System Lockout (Retries or Recycles exceeded)
3 Flashes ---
Draft Pressure Error - Possible problems
a) Venting problem
b) Pressure switch problem
c) Inducer problem
4 Flashes --- Open High Limit Device
5 Flashes --- Flame sensed when no flame should be present
6 Flashes --- 115 Volt AC power reversed or Poor Grounding
7 Flashes --- Gas valve circuit error
8 Flashes --- Low flame sense signal
9 Flashes ---
Check Ignitor circuit and Line "N" to 24VAC "Com-
mon" voltage (< 2volts)
(possible grounding problem)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane ADH1B065A9421A and is the answer not in the manual?

Trane ADH1B065A9421A Specifications

General IconGeneral
BrandTrane
ModelADH1B065A9421A
CategoryFurnace
LanguageEnglish

Related product manuals