16
I
D
GB
F
E
DATOS TECNICOS
EFICACIA
RENDIMIENTO
BICIRCUITO
60 HZ
DONNÉE
TECHNIQUES
RENDEMENT
BI-CIRCUIT
60 HZ
TECHNISCHEN DATEN
ERBRACHTE
LEISTUNG
ZWEIKREISIG
60 HZ
TECHNICAL DATA
60 HZ
BI-CIRCUIT
PERFORMANCE
CAPACITY
DATI TECNICI
PERFORMANCE
RESA BI-CIRCUITO
60 HZ
Text
[°C]
Velocità ventilatori
Fan Speed
Ventilatordrehzahl
Vitesse de rotation
Velocidad de rotación
Portata d’aria
Air volume
Luftleistung
Débit d’air
Caudal de aire
Tcond
[°C]
[%] [m³/h]
CAP 1802
43 5891 [kW]
56 8476 [kW]
70 11386 [kW]
100 17500 [kW]
CAP 2002
43 5674 [kW]
56 8147 [kW]
70 10964 [kW]
100 16900 [kW]
CAP 3002
43 9280 [kW]
56 13369 [kW]
70 17963 [kW]
100 27500 [kW]
CAP 4002
43 8912 [kW]
56 12759 [kW]
70 17104 [kW]
100 26250 [kW]
CAP 5002
43 11927 [kW]
56 17040 [kW]
70 22827 [kW]
100 35000 [kW]
CAP 6002
43 15479 [kW]
56 22136 [kW]
70 29594 [kW]
100 45000 [kW]
CAP 7002
43 14726 [kW]
56 20838 [kW]
70 27740 [kW]
100 42250 [kW]
Temperatura aria esterna
Temperatura satura
di condensazione
External air temperature
Saturated condensing
temperature
Außenlufttemperatur
Kondensationstemperatur
Temperature extérieure
Temperature de condensation
Temperatura exterior
Temperatura de condensacn
Text:
Tcond :

Related product manuals