EasyManua.ls Logo

Trane Hyperion TAM8A0B30V21CA User Manual

Trane Hyperion TAM8A0B30V21CA
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
© 2011 Trane
NOTICE: Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.
IMPORTANT --- This document contains a wiring diagram and service information. This is customer property and is to remain with this unit.
Please return to service information pack upon completion of work.
Air Handler - Convertible
Models: Series 8 Air Handlers 2-5 Ton
HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
WARNING:
HyperionFieldReferenceDataTAM8
For use with BAYEV or BAYW series heaters ONLY
WARNING
!
SAFETY HAZARD! This information is intended for use
by individuals possessing adequate backgrounds of electrical and
mechanical experience. Any attempt to repair a central air condition-
ing product may result in personal injury and/or property damage.
The manufacture or seller cannot be responsible for the interpreta-
tion of this information, nor can it assume any liability in connection
with its use.
PRESSURIZED REFRIGERANT! SYSTEM CONTAINS
OIL AND REFRIGERANT UNDER HIGH PRESSURE. RECOVER
REFRIGERANT TO RELIEVE PRESSURE BEFORE OPENING THE
SYSTEM.
DO NOT USE NON-APPROVED REFRIGERANTS OR REFRIGERANT
SUBSTITUTES OR REFRIGERANT ADDITIVES.
WARNING
!
LIVE ELECTRICAL COMPONENTS! During instal-
lation, testing, servicing, and troubleshooting of this product, it may
be necessary to work with live electrical components. Failure to fol-
low all electrical safety precautions when exposed to live electrical
components could result in death or serious injury.
WARNING
!
Note: This unit is certified to UL 1995.
The interior cabinet wall meets the following:
- UL94-5VA Flame Class Listed
- UL723 Steiner Tunnel Listed for 25/50 Flame/
Smoke
- UL746C Listed for Exposure to Ultraviolet Light,
Water Exposure and Immersion
NOTE: This unit as shipped is ONLY compatible with
Trane and American Standard communicating thermostats
and outdoor units. (24VAC thermostats cannot be used)
With the addition of a BAYCC24VK01 accessory, this unit
can be compatible with a 24VAC single or multistage heat
pump or air conditioner.
Table of Contents
Product Specifications. .................................................................................................... 2
Wiring Diagram. ............................................................................................................... 3
Sequence of Operation. ................................................................................................... 4
Control Layout - Refrigerant Dip Switch .......................................................................... 6
Airflow Performance. ........................................................................................................ 7
Heater Attribute Data. .................................................................................................... 13
Control Layout - LEDs. ................................................................................................... 16
Alert Codes. ................................................................................................................... 22
EEV Test Procedures. .................................................................................................... 23
EVC Thermal Resistance and Voltage Table. ................................................................ 24
AFC Supply Air Temperature Sensor Table. ................................................................... 25
Display Assembly Menus. .............................................................................................. 26
Troubleshooting. ............................................................................................................ 32
*AM8A0A24V21CA, *AM8A0B30V21CA
*AM8A0C36V31CA, *AM8A0C42V31CA
*AM8A0C48V41CA, *AM8A0C60V51CA
* May be "A" or "T"
Question and Answer IconNeed help?

Do you have a question about the Trane Hyperion TAM8A0B30V21CA and is the answer not in the manual?

Trane Hyperion TAM8A0B30V21CA Specifications

General IconGeneral
Model NumberTAM8A0B30V21CA
TypeAir Handler
SeriesHyperion
Cooling Capacity2.5 tons
Voltage208/230 V
Phase1
Width (in)21
Depth (in)21
Weight130 lbs
Maximum External Static Pressure0.8 in. w.c.
CabinetGalvanized Steel
Blower TypeVariable Speed ECM
AirflowVariable
Sound LevelQuiet
Heating Capacity30, 000 BTU/h
SEER RatingUp to 21 SEER
HSPF RatingUp to 10 HSPF

Summary

General Safety Warnings

Hazardous Voltage and Electrical Safety

Warning about high voltage and disconnecting power before servicing.

Product Safety Hazard and Refrigerant Warnings

Warning for trained individuals and pressurized refrigerant system safety.

Product Specifications

Wiring Diagram and Components

AM8 Air Handler Wiring Diagram

Visual guide to electrical connections for the AM8 Air Handler.

Sequence of Operation - Core Modes

Sequence of Operation - Advanced Features

Control System Management

Control Panel Interface

Airflow Control (AFC) Status and Faults

AFC Fault Codes and Descriptions

Lists Red LED fault codes and their corresponding error descriptions for AFC.

Expansion Valve Control (EVC) Status and Faults

EVC Fault Codes and Descriptions

Lists Red LED fault codes and their corresponding error descriptions for EVC.

Electric Heat Control (EHC) Status and Faults

Hydronic Heat Control (HHC) Status and Faults

Alert Code Reference

Alert Codes and Descriptions

Comprehensive table of alert codes, descriptions, and possible causes.

Electronic Expansion Valve (EEV) Testing

EEV Test Procedures Overview

Steps for performing EEV tests via the Display Assembly.

EEV Close and Open Valve Tests

Detailed instructions for Close Valve and Open Valve tests.

EVC Sensor Data Tables

AFC Supply Air Temperature Sensor Data

Display Assembly Interface

Display Assembly Menu Structure

System Monitoring Functions

Technician Monitor Menu Options

Details on monitoring system parameters like EEV position, superheat, and airflow.

Alert History and Management

Configuration Menu Options

Control Menu Functions

EVC Test Procedures

Steps for performing EEV OPEN and CLOSE tests.

Troubleshooting - Sensor Issues

Sensor Check Troubleshooting Flowchart

Step-by-step guide to diagnose issues with temperature sensors.

Sensor Resistance and Ground Check

Procedures for measuring sensor resistance and checking for shorts to ground.

Troubleshooting - High Superheat

High Superheat Diagnosis Flowchart

Guide to diagnose and resolve high superheat conditions.

EEV and Coil Testing for Superheat

Procedures for testing EEV and coils when diagnosing high superheat.

Troubleshooting - Low Superheat

Low Superheat Diagnosis Flowchart

Guide to diagnose and resolve low superheat conditions.

EEV and Coil Testing for Low Superheat

Procedures for testing EEV and coils when diagnosing low superheat.