EasyManua.ls Logo

Trane Hyperion TAM8A0C60V51CA User Manual

Trane Hyperion TAM8A0C60V51CA
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
© 2011 Trane
NOTICE: Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.
IMPORTANT --- This document contains a wiring diagram and service information. This is customer property and is to remain with this unit.
Please return to service information pack upon completion of work.
Air Handler - Convertible
Models: Series 8 Air Handlers 2-5 Ton
HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
WARNING:
HyperionFieldReferenceDataTAM8
For use with BAYEV or BAYW series heaters ONLY
WARNING
!
SAFETY HAZARD! This information is intended for use
by individuals possessing adequate backgrounds of electrical and
mechanical experience. Any attempt to repair a central air condition-
ing product may result in personal injury and/or property damage.
The manufacture or seller cannot be responsible for the interpreta-
tion of this information, nor can it assume any liability in connection
with its use.
PRESSURIZED REFRIGERANT! SYSTEM CONTAINS
OIL AND REFRIGERANT UNDER HIGH PRESSURE. RECOVER
REFRIGERANT TO RELIEVE PRESSURE BEFORE OPENING THE
SYSTEM.
DO NOT USE NON-APPROVED REFRIGERANTS OR REFRIGERANT
SUBSTITUTES OR REFRIGERANT ADDITIVES.
WARNING
!
LIVE ELECTRICAL COMPONENTS! During instal-
lation, testing, servicing, and troubleshooting of this product, it may
be necessary to work with live electrical components. Failure to fol-
low all electrical safety precautions when exposed to live electrical
components could result in death or serious injury.
WARNING
!
Note: This unit is certified to UL 1995.
The interior cabinet wall meets the following:
- UL94-5VA Flame Class Listed
- UL723 Steiner Tunnel Listed for 25/50 Flame/
Smoke
- UL746C Listed for Exposure to Ultraviolet Light,
Water Exposure and Immersion
NOTE: This unit as shipped is ONLY compatible with
Trane and American Standard communicating thermostats
and outdoor units. (24VAC thermostats cannot be used)
With the addition of a BAYCC24VK01 accessory, this unit
can be compatible with a 24VAC single or multistage heat
pump or air conditioner.
Table of Contents
Product Specifications. .................................................................................................... 2
Wiring Diagram. ............................................................................................................... 3
Sequence of Operation. ................................................................................................... 4
Control Layout - Refrigerant Dip Switch .......................................................................... 6
Airflow Performance. ........................................................................................................ 7
Heater Attribute Data. .................................................................................................... 13
Control Layout - LEDs. ................................................................................................... 16
Alert Codes. ................................................................................................................... 22
EEV Test Procedures. .................................................................................................... 23
EVC Thermal Resistance and Voltage Table. ................................................................ 24
AFC Supply Air Temperature Sensor Table. ................................................................... 25
Display Assembly Menus. .............................................................................................. 26
Troubleshooting. ............................................................................................................ 32
*AM8A0A24V21CA, *AM8A0B30V21CA
*AM8A0C36V31CA, *AM8A0C42V31CA
*AM8A0C48V41CA, *AM8A0C60V51CA
* May be "A" or "T"
Question and Answer IconNeed help?

Do you have a question about the Trane Hyperion TAM8A0C60V51CA and is the answer not in the manual?

Trane Hyperion TAM8A0C60V51CA Specifications

General IconGeneral
BrandTrane
ModelHyperion TAM8A0C60V51CA
CategoryAir Handlers
LanguageEnglish

Summary

Safety and Warnings

General Safety Precautions

Covers hazardous voltage, safety hazards, live components, and refrigerant safety.

Product Specifications

Wiring Diagram and Electrical Information

Wiring Diagram and Legend

Electrical connection diagram, symbols, and safety warnings for the air handler.

Sequence of Operation

System Operation Modes

Details on continuous fan, cooling, heatpump, and electric heat sequences.

Advanced Operational Features

Fault Management and Configuration

Fault Reporting and Clearing

Procedures for viewing and clearing system faults from control boards.

System Settings and Adjustments

AFC Control Board Details

AFC Fault Codes

Lists fault codes for the AFC board and their descriptions.

EVC Control Board Details

EVC Fault Codes

Lists fault codes for the EVC board and their descriptions.

EHC Control Board Details

HHC Control Board Details

Alert Code Reference

Alert Codes and Descriptions

Comprehensive list of alert codes, their meanings, and possible causes.

Electronic Expansion Valve (EEV) Testing

EEV Test Options and Procedures

Details on testing EEV using the display assembly or board pins.

EVC Sensor Data

AFC Sensor Data

Display Assembly Operation

System Monitoring Features

Alert Menu Functions

Alert Menu Navigation and Components

Explains how to view active/historical faults and abbreviations.

Configuration Menu Settings

Control Menu Functions

Control Menu Operations

Describes EVC Test, Control CFM, and Unit Test procedures.

Troubleshooting Guide

Sensor Troubleshooting Flowchart

Step-by-step guide to diagnose sensor issues.

High Superheat Troubleshooting

High Superheat Diagnosis

Flowchart to diagnose and resolve high superheat conditions.

Low Superheat Troubleshooting

Low Superheat Diagnosis

Flowchart to diagnose and resolve low superheat conditions.