EasyManuals Logo

Trane S8V2C100M5PC User Manual

Trane S8V2C100M5PC
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #68 background imageLoading...
Page #68 background image
68
S8V2-SVX001-1A-EN
DEFINITION:
Flame is sensed when it
should not be sensed.
Is there a drip leg installed
on inlet gas piping per
installaon instrucons?
Using a back-up wrench,
install new gas valve
Check operaon
Inspect gas supply
for leaks and have
gas supplier check
gas quality
Are there signs of
moisture or debris in the
inlet gas screen?
YES
Install drip leg per
Naonal Fuel Gas
Code and
Installaon
Instrucons
YES
NO
Disconnect electrical
power to furnace
5.0 Fault Code
NO
Turn off gas supply!
Remove gas valve
TTrroouubblleesshhoooottiinngg