46
Installation - Electrical Connections
Rooftop Connections
1. Route the power harness from the Refrigeration Module to the Power
Pack Module.
2. Connect the 12-pin connector to the mating connector on the Power
Pack Module.
3. Insert the two electrical barrel connectors (2R-01) and (CH10) into the
mating terminal connector block on the Power Pack and tighten
securely.
4. Connect the Condenser Fan Motor connectors (CF1-01, CFI) and
(CF2, CHK) to the mating connectors in both the Power Pack Module
and at the Condenser Module.