WALL-MOUNT AIR HANDLERS
2-3TON COOLING/HEAT PUMP
TMM5B0A24M21SAA
TMM5B0B30M21SAA
TMM5B0B36M31SAA
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
Important: This Document is customer property and is to remain with this unit.
Installer’s Guide
Section 1. Features
1.1 Standard Features
1.2 Optional Accessories
5, 7.5 and 10 kW SINGLE PHASE ELECTRIC
HEATERS
- Circuit breakers are standard on all single
phase 5,
7.5 and 10 kW heaters.
The TMM5B series wall mount air handler is designed for installation in a closet, utility room, alcove
and can be wall mounted. These versatile units are applicable to air conditioning and heat pump
applications. Field installed electric resistance heaters are available.
All aluminum coil.
Blower and coil slide out easily for maintenance.
Factory-sealed cabinet certified to achieve 2% or
less air leakage rate at 1.0 inch water column.
Front or bottom return air.
Painted finish on galvanized steel.
Sturdy polycarbonate drain pans.
- Air handler has factory installed drain pans and
is shipped for upflow applications only.
208/230 VAC operation.
Multi-speed direct drive blower constant torque
ECM motor with fan-off time delay programming.
Factory installed R-410A thermal expansion
valve.
Stud or wall mounting installation.
Fully insulated cabinet.
3/4'' NPT primary and secondary drains.
AHRI certifird and ETL listed.
18-GF13D1-1A-EN
Question and Answer IconNeed help?

Do you have a question about the Trane TMM5B0B36M31SAA and is the answer not in the manual?

Trane TMM5B0B36M31SAA Specifications

General IconGeneral
BrandTrane
ModelTMM5B0B36M31SAA
CategoryAir Conditioner
LanguageEnglish

Summary

Section 2. Safety Information

Section 3. Installation Instructions

3.3 Duct Work

Guidelines for designing and installing ductwork, emphasizing compliance with codes and performance.

3.4 Condensate Drain

Instructions for correctly installing condensate drains, including trapping and pitching requirements.

3.5 Refrigerant Piping

Procedures for refrigerant piping connections, pressure testing, and protection during brazing.

3.8 Wiring

Instructions for field wiring, including power wiring, control wiring, and grounding requirements.

3.8.1 POWER WIRING

Essential information on electrical power requirements, circuit protection, and connection points.

3.8.3 GROUNDING

Critical steps for permanently grounding the unit to prevent electrical shock hazards.

Section 4. Wiring

Section 6. Performance and Electrical Data