EasyManua.ls Logo

Trane *UH1B040A9241A User Manual

Trane *UH1B040A9241A
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Upflow/ Horizontal, Downflow/ Horizontal,
Gas-Fired, Direct Vent Condensing
Furnaces
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT This Document is customer property and is to remain with this unit.
Please return to service information pack upon completion of work.
Installer’s Guide
*__First letter may be “A” or “T”
18- CD29D1- 3
UPFLOW
*UH1
UPFLOW/HORIZONTAL
A341624P13
*UH1
*UH1B040A9241A
*UH1B060A9361A
*UH1B080A9421A
*UH1C080A9601A
*UH1C100A9481A
*UH1D100A9601A
*UH1D120A9601A
*DH1B040A9241A
*DH1B065A9421A
*DH1C085A9481A
*DH1D110A9601A
*DH1
DOWNFLOW
DOWNFLOW/HORIZONTAL
*DH1
Question and Answer IconNeed help?

Do you have a question about the Trane *UH1B040A9241A and is the answer not in the manual?

Trane *UH1B040A9241A Specifications

General IconGeneral
Model NumberUH1B040A9241A
CategoryFurnace
TypeGas
Input BTU40, 000
Blower TypeMulti-Speed
StagesSingle Stage
Gas Valve TypeStandard
Ignition TypeHot Surface Ignition
Heat Exchanger MaterialAluminized Steel
Fuel TypeNatural Gas
Warranty5-Year Limited Warranty on Parts

Summary

SAFETY SECTION

WARNING and CAUTION Signals

Explains the meaning of safety signal words used in the manual.

CARBON MONOXIDE POISONING HAZARD

Details risks and steps to prevent carbon monoxide poisoning during operation.

FIRE OR EXPLOSION HAZARD

Highlights dangers of fire or explosion due to improper installation or handling.

EXPLOSION HAZARD

Warns about propane gas heavier than air and the need for detectors.

SAFETY HAZARD

Emphasizes risks of improper gas pressure adjustment and leak checks.

GENERAL INSTALLATION INSTRUCTIONS

Location and Clearances

Specifies requirements for furnace placement and necessary clearances around the unit.

Upflow/Horizontal Installation

Provides outline drawing and dimensional data for upflow/horizontal furnace models.

Downflow/Horizontal Installation

Provides outline drawing and dimensional data for downflow/horizontal furnace models.

Air For Combustion and Ventilation

Details requirements for adequate airflow for combustion and ventilation.

Duct Connections

Explains how to connect supply and return air ductwork to the furnace.

Return Air Filters

Describes the installation and types of optional return air filters.

GENERAL VENTING

Venting Material and Joints

Covers specifications for plastic vent pipe material, fittings, and joint sealing.

Venting Through the Wall

Details the process for venting the furnace through exterior walls.

Venting Through the Roof

Explains how to properly vent the furnace through a roof opening.

Venting Through Floor

Outlines the procedure for venting a furnace through the floor.

CONDENSATE DRAIN INSTRUCTIONS

Upflow Furnace Condensate Drainage

Instructions for connecting condensate drain tubing for upflow furnaces.

Downflow Furnace Condensate Drainage

Instructions for configuring condensate drain for downflow furnaces.

Condensate Drain Piping

Explains manifolding of drain pipes and requirements for preventing freeze-up.

ELECTRICAL CONNECTIONS

Wiring Diagram for 1 Stage Furnace

Provides a wiring diagram for single-stage heating and cooling configurations.

Twinning Furnace Connections

Details wiring diagrams for connecting two furnaces in a twinning configuration.

GAS PIPING

Gas Piping Installation

Covers requirements for connecting the gas supply line to the furnace.

Combustion and Input Check

Outlines the procedure for checking combustion and input rates.

Gas Valve Adjustment

Explains how to adjust the gas valve manifold pressure for proper operation.

HIGH ALTITUDE DERATE

Orifice Selection for Altitude

Guides on selecting replacement orifices based on altitude and input rate.

Lighting Instructions

Provides instructions for safely lighting the furnace burner.

SEQUENCE OF OPERATION

Control and Safety Switch Adjustments

Details how to check and adjust safety controls like limit switches.

Airflow Adjustment

Describes how to check and adjust airflow by changing blower motor speed.

ABNORMAL CONDITIONS

Troubleshooting Common Issues

Lists common abnormal conditions and their potential causes/resolutions.

INTEGRATED FURNACE CONTROL ERROR FLASH CODES