SAFETY WARNING
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-
conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment
by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and
on the tags, stickers, and labels that are attached to the equipment.
Packaged Rooftop Air Conditioners
Voyager
Heat Pump
12½ – 20 Ton, 60/50 Hz
Installation, Operation,
and Maintenance
Model Numbers
WS*150-240
RT-SVX33E-EN
May 2014
Question and Answer IconNeed help?

Do you have a question about the Trane Voyager WS 150-24 and is the answer not in the manual?

Trane Voyager WS 150-24 Specifications

General IconGeneral
ModelVoyager WS 150-24
CategoryAir Conditioner
Phase3
Frequency60 Hz
Compressor TypeScroll
RefrigerantR-410A
Cooling Capacity150 tons
Voltage460V
Heating CapacityVaries with heating option (Gas, Electric, Hot Water)

Summary

Warnings, Cautions and Notices

Personal Protective Equipment (PPE) Required!

Discusses safety gear needed for installation and servicing, including specific types and guidelines.

Proper Field Wiring and Grounding Required!

Emphasizes the need for qualified personnel for field wiring and grounding to prevent fire and electrocution hazards.

General Information

Unit Inspection

Details steps for checking the unit upon arrival, including verifying nameplate data and inspecting for shipping damage.

Unit Clearances

Explains minimum operating and service clearances for installation to ensure proper operation and accessibility.

ReliaTel™ Control

Unit Weights

Rigging

Provides instructions and safety warnings for lifting the unit, including rigging points and load balancing.

Installation

Electrical Requirements

Details power supply verification, wiring, grounding, and control wiring standards for safe installation.

Main Unit Power and Wiring

Covers standard, optional, and field-installed power wiring, control wiring, and transformers.

Pre-Start

Start Up

Maintenance

Troubleshooting

ReliaTel Controls Diagnostics

Guides on checking RTRM status, LED indicators, and performing system status checkout procedures.

System Status Checkout Procedure

Details methods for checking unit status via LED indicators or voltage readings at RTRM terminals.

Failure Indications and Lockout Reset

Lists common failure causes and provides methods to reset cooling and heating lockouts.

Component Status Indicators and Tests

Explains ZTS indicators, clogged filter/fan failure/overflow switches, and ZTS testing procedures.

Zone Sensor and Communication Tests

Covers testing programmable/digital zone sensors, serial communication voltage, and temporary operation without a zone sensor.

Unit Economizer Control (ECA) Troubleshooting