Filling:
1. Place an empty container onto the scale.
2. Press the TARE key.
The display shows the net value and the pointers stp1 and stp2 are on.
Relays 1 and 2 are closed.
3. As soon as set-point 1 is reached, pointer stp1 will turn off and relay 1 will be opened.
4. As soon as set-point 2 is reached, pointer stp2 will turn off and relay 2 will be opened.
5. The display shows “done” for a few seconds and then returns to the normal weighing
mode.
The net weight is displayed. A printout may be made at this point.
Cancel the filling procedure at any time by pressing the NET/GROSS key (see Cancelling
the dosing or filling).
Dosing:
1. Place a full container on the scale.
2. Press the TARE key.
The display shows the net value and the pointers stp1 and stp2 are on.
Relays 1 and 2 are closed.
3. As soon as set-point 1 is reached, pointer stp1 will turn off and relay 1 will be opened.
4. As soon as set-point 2 is reached, pointer stp2 will turn off and relay 2 will be opened.
5. The display shows “done” for a few seconds and returns in the normal weighing mode.
6. The net weight is displayed. A printout may be made at this point.
Cancel the filling procedure at any time by pressing the NET/GROSS key (see Cancelling
the dosing or filling).
The printout will show the following:
- The gross weight is the weight of the container with rest material.
- The tare weight is the weight of the container with material before dosing.
- The net weight will show a minus sign as token of weight being removed from the scale.
Dosing/filling with automatic start
In this application, set-point 1 and 2 are switched on as soon as the set-point values have been
entered.
Attention: The tare action is done automatically in this mode. Be sure the container is in
place before starting!
To enter new set-point values:
1. Press the NET/GROSS key.
The display shows the last entered value with the left digit blinking. The pointer for
set-point 1 is on.
2. Press NET/GROSS to accept the old value.
The display shows the last entered value with the left digit blinking. The pointer for
set-point 2 is on.

Other manuals for Transcell Technology TI-500 RF Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Transcell Technology TI-500 RF Series and is the answer not in the manual?

Transcell Technology TI-500 RF Series Specifications

General IconGeneral
BrandTranscell Technology
ModelTI-500 RF Series
CategoryTouch Panel
LanguageEnglish

Related product manuals