E-100BTX-FX-04 IN THE NETWORK
Copper Cable
Category 5 shielded twisted-pair (STP) or unshielded twisted-pair (UTP) copper
wire is required. DO NOT USE FLAT OR SILVER SATIN WIRE.
CATEGORY 5:
Gauge 24 to 22 AWG
Attenuation 22.0 dB /100m @ 100 MHz
Maximum Cable Distance: 100 meters
TECHNICAL SPECIFICATIONS
Standards IEEE 802.3u
Case Dimensions 4.75" x 3.0" x 1.0"(119mm x 76mm x 25mm)
Shipping Weight 3 pounds (1.4 kilograms)
Delay 400nsec round trip
Environment Temperature: 0-40°C (32° to 104° F )
Humidity 10-90%, non condensing
Altitude 0-10,000 feet
Power Supply Requirements Replace power supply with only the equivalent
input rating (see below) and output rating (regulated 9VDC at 550 mA).
TN PN Requirement Location
3525 240 volts, 50 hertz United Kingdom
3525 230 volts, 50 hertz Europe
3518 120 volts, 60 hertz USA/Canada/Mexico
3514 100 volts, 50-60 hertz Japan
3525 240 volts, 50 hertz Australia
NOTE: This product can be powered by the E-MCR series media converter rack.
Warranty Lifetime
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA
Model: E-100BTX-FX-04 Series Media Converters
Part Number(s): E-100BTX-FX-04, E-100BTX-FX-04(SC), E-100BTX-FX-04(MT),
E-100BTX-FX-04(SM), E-100BTX-FX-04(SMLC), E-100BTX-FX-04(LH),
E-100BTX-FX-04(XL), E-100BTX-FX-04(LW)
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the E-100BTX-FX-04 to which this declaration refers is
in conformity with the following standards.
EMC-CISPR 22: 1985 Class A; EN 55022: 1988 Class A; EN 50082-1:1992;
EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950
I, the undersigned, hereby declare that the equipment specified above conforms to the
above Directive(s) and Standard(s).
_August 1, 1999_____
Stephen Anderson, Vice-President of Engineering Date
Switches at the side of the media converter are used to configure the media
converter for the network.
MDI/MDI-X SWITCH
Allows straight-through twisted-pair cable to be
used for crossover 100BASE-TX connections.
4-POSITION SWITCH
1(UP) Enables Auto-negotiation function to detect and adapt to line
speed/operation mode of attached device. (DOWN) Disables Auto-
negotiation function.
2(UP) Allows an attached full-duplex station to transmit and receive
simultaneously. (DOWN) Allows an attached half-duplex station to transmit
and receive sequentially.
3(UP) Enables BOTH Link Pass Through AND Remote Fault Detect functions.
(See page 4) (DOWN) Disables BOTH Link Pass Through AND Remote Fault
Detect functions
4 Relevant only if Switch 3 is UP. (UP) Enables Remote Fault Detect function
at Switch 3. (DOWN) Disables Remote Fault Detect function at Switch 3.
Do NOT connect media
converters between hubs.
Install no more than two (2)
media converters in series.
The two active pairs in a 100BASE-TX
network are pins 1 & 2 and pins 3 & 6. Use
only dedicated wire pairs (such as
blue/white & white/blue, orange/white &
white/orange) for the active pins.