CABLE SPECIFICATIONS
The physical characteristics of the media cable must meet or exceed IEEE 802.3 specifications.
Fiber Cable
Bit error rate: 10-9
MULTIMODE
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber
Optional: 100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber
E-100BTX-FX-04 1300 nM
Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm
Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm
Typical Maximum Cable Distance*: 2 kilometers
E-100BTX-FX-04(SC) 1300 nM
Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm
Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm
Typical Maximum Cable Distance*: 2 kilometers
E-100BTX-FX-04(MT) 1300 nM
Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm
Fiber Optic Receiver Sensitivity: min: -33.5 dBm max: -14.0 dBm
Typical Maximum Cable Distance*: 2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended: 9 µm singlemode fiber
E-100BTX-FX-04(SM) 1300 nM
Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm
Fiber-optic Receiver Sensitivity: min: -32.5 dBm max: -8.0 dBm
Typical Maximum Cable Distance*: 20 kilometers
E-100BTX-FX-04(SMLC) 1300 nM
Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm
Fiber-optic Receiver Sensitivity: min: -32.5 dBm max: -3.0 dBm
Typical Maximum Cable Distance*: 20 kilometers
E-100BTX-FX-04(LH) 1300 nM
Fiber-optic Transmitter Power: min: -8.0 dBm max: 0.0 dBm
Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -8.0 dBm
Minimum Attenuation: 8 dB
Typical Maximum Cable Distance*: 40 kilometers
E-100BTX-FX-04(XL) 1310 nM
Fiber-optic Transmitter Power: min: -5.0 dBm max: 0.0 dBm
Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm
Minimum Attenuation: 7 dB
Typical Maximum Cable Distance*: 60 kilometers
E-100BTX-FX-04(LW) 1550 nM
Fiber-optic Transmitter Power: min: -5.0 dBm max: 0.0 dBm
Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm
Spectral Width 0.4 nm FWHM
Minimum Attenuation: 7 dB
Typical Maximum Cable Distance*: 80 kilometers
*Actual distance dependent upon physical characteristics of network installation.
INSTALLATION
Set Switches
Use small flatblade
screwdriver or
similar device to set
recessed switches
according to site
installation.
Set the
MDI/MDI-X
switch to MDI
for cable connection between hub and media converter. Set the
MDI/MDI-X switch to MDI-X for cable connection between media
converter and terminal, transceiver or network interface card (NIC).
Refer to drawing for four-position switch settings.
Install Cable
COPPER
NOTE: KEEP TWISTED PAIR RUNS AS SHORT AS POSSIBLE.
Locate or build 802.3 compliant cables with straight through
configuration and male RJ-45 plug connectors.
Connect male RJ-45 plug connector at one end of cable to media
converter RJ-45 jack connector.
Connect male RJ-45 plug connector at other end of cable to DTE
terminal RJ-45 jack connector (setting MDI switch to MDI-X) or to Hub
RJ-45 jack connector (setting MDI switch to MDI).
FIBER
Locate or build 802.3 compliant fiber cable with male two-stranded TX
to RX connectors appropriate to the media converter installed at both
ends.
Connect male TX and RX cable connectors at one end of cable to TX
and RX female connectors, respectively, on media converter.
Connect male TX and RX cable connectors at other end of cable to RX
and TX connectors of 802.3 compliant fiber device.
Connect to Power
Install Power Adapter cord at back of media converter.
Connect Power Adapter 3-prong plug to AC power.
Verify that media converter is powered by observing illuminated LED(s).
MDI
MDI-X
E
-
1
0
0
B
T
X
-
F
X
-
O
4
9V DC Input
Config
Switches
1 2 3 4
LPT/RFD UP=ON
Auto-negotiation UP=ON
Full/Half-duplex UP=FULL
RFD UP=ON
MDI
position
MDI-X
position