8 Installation
3.2 Flowmeter connections ( un-powered sensors )
For Intrinsically Safe installations refer to I.S. supplement manual.
Installation 9
3.2 Flowmeter connections ( powered sensors )
For Intrinsically Safe installations refer to I.S. supplement manual.
DIP switch 2 in
the ON position
( 250 hz max.)
NOTE : Voltage not to exceed 13.4 Vdc
through an approv ed barrier if when using
an intrinsically saf e NAMUR proximity in a
hazardous area ( EEx Ia 11C ). Ty pically
these proximity ’s are limited to 8.2 Vdc
NAMUR
Inductive Proximity
Hall effect input
( NPN open collector )
DIP switch 1 in
the ON position
NOTE: For an input
>800hz position a ¼
watt resistor across
terminals 1 & 4,
12Vdc: 1Meg Ω
24Vdc: 2Meg Ω
Modulated current
pulse input (4~20mA)
All DIP switches
to be in the OFF
position
Coil w ith pre-amp
current modulated
NOTE: Position a 100 ohm,
¼ watt resistor across
terminals 1 & 3 as shown
Coil input from
turbines or paddle
DIP switch 1 in
the ON position
( 5 Khz max.)
Screen grounded at
amphenol shroud or
terminal box
and terminal 3
DIP switches
1 & 3 (de-bounce)
in the ON position
( 40 hz max.)
Note: DIP sw itch 3 is to be
OFF for reed switch input
frequencies greater than 40 hz.
Voltage pulse
input (pulse wire)
All DIP switches
to be in the OFF
position