EasyManua.ls Logo

Trimec RT12 Series User Manual

Trimec RT12 Series
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
IMBT000-3210
I N S T R U C T I O N M A N U A L
BATTERY TOTALISER
Universal Mount Series
Declaration of Conformity
Trimec Industries Pty Ltd declares under sole responsibility that the products :
Flow Rate Totaliser model : RT12…, and Totaliser mo del : BT11
to w hich this declaration relates are in conformity with the standards noted below :
EN 50014 : 1997 + Amds. 1 & 2 I. S. Intrinsically safe electronics (optional) & there are no changes
required to enable compliance to the replacement standards EN 60079-0:2006 and EN 60079-1:2004.
EN 50020 : 2002 I.S. Intrinsically safe electronics (optional).
In addition & also applying to the model EB Batch Controller are the follow ing standards:
EN 60529 : 1991 Degrees of protection (IP)
EN 61326 : 1998 Industrial electromagnetic immunity & emissions
2002/96/EC Waste electrical & electronic equipment (WEEE).
Issued at Taren Point 28
th
January 2010. Signed for and on behalf of Trimec Industries Pty Ltd.
Wayne Fuller, Director
Question and Answer IconNeed help?

Do you have a question about the Trimec RT12 Series and is the answer not in the manual?

Trimec RT12 Series Specifications

General IconGeneral
Process ConnectionNPT, BSP, or Flanged
Operating Temperature-40°F to +250°F (depending on model and fluid)
Flow Rate Range0.1 to 150 GPM
Materials of ConstructionStainless Steel
Output SignalPulse, 4-20mA
Measurement Range0.1 to 150 GPM
DisplayLCD

Summary

Declaration of Conformity

INTRODUCTION

Specifications

Outlines the technical specifications including display, signal inputs, powering, pulse output types, physical characteristics, and configuration options.

INSTALLATION

Flowmeter connections (un-powered sensors)

Details how to connect un-powered sensors such as Reed switches, coil inputs, and voltage pulse inputs.

Flowmeter connections (powered sensors)

Details how to connect powered sensors like Namur proximity detectors and Hall effect inputs.

Current Sinking outputs (NPN)

Describes the wiring and configuration for NPN pulse outputs, used for current sinking applications.

Current Sourcing outputs (PNP)

Describes the wiring and configuration for PNP pulse outputs, used for current sourcing applications.

PROGRAM PARAMETERS

PIN No. Program Protection

Explains the PIN protection feature to secure programmed details and the accumulated total.

TROUBLESHOOTING