INSTAFLOW
16
1 Water not hot
enough.
2 Water too hot.
3 Heater switches off
during use.
4 Water ceases to
flow.
5 Water temperature
varies from hot to
cold during use.
6 Water flow too
low, POWER light
OFF.
1.1 Too much water
flowing through the
heater.
1.2 Reduction in the
ambient temperature.
1.3 Electrical
malfunction.
2.1 Not enough water
flowing through the
heater.
2.2 Increase in the
ambient temperature.
3.1 Interruption of mains
electrical supply.
3.2 RCD trip, possible
earth leakage.
4.1 Blockage of tap.
4.2 No water supply.
5.1 Water pressure has
dropped below minimum
level.
6.1 Flow rate too low to
activate the heater.
1.1.1 Reduce the flow rate of the water via the
outlet taps.
1.2.1 Switch to higher power setting.
1.3.1 Have the heater checked by a qualified
electrican or contact Triton Customer Service.
2.1.1 Increase the flow rate.
2.2.1 Switch to lower power setting.
3.1.1 Check loss of power, MCB, switches and
supply cabling.
3.2.1 Check earth leakage.
4.1.1 Clean/renew tap, check for free passage
of water. Replace as necessary.
4.2.1 .Check water supply. Is stop valve open?
Check for blockage.
5.1.1 Check for stable flow through the heater
unit.
6.1.1 Increase water flow. Check water supply.
Is stop valve fully open? Check for blockage.
FAULT FINDING
IMPORTANT: Switch off the electricity at the mains supply and remove the circuit fuse
before attempting any fault finding inside the unit.
It is advised that all electrical repairs/maintenance to the heater should be carried out
by a suitably qualified person.
Problem/Symptom Possible causes Action/cure