9
CV Discription DCC Value Factory
Setting, DCC
/ SX
Selectrix Value
1 address 1 - 127 3 / 1 1 - 99
3 acceleration delay 0 - 255 3
3
1 - 7
4 braking delay 0 - 255 4 1 - 7
5 * maximum speed 0 - 127 127 / 7 1 - 7
17 extendet address (upper part) CV 29, Bit 5=1 195 / — not necessary
18 extendet address (lower part) CV 29, Bit 5=1 0 / — not necessary
29
Bit0:Traveldirectionpolarityreversal
Bit1:numberofspeedlevels14/28
Bit2:DCCOperationwithbrakingBlock
DCC-, Selectrix and DC power operation
Bit5:addresssize7Bit/14Bit
Value
0 / 1
0 / 2
0 / 4
0 / 32
***
0, 1, 2, 3, 4, 5, 6, 7,
32, 34, 35, 36, 37,
38, 39
6 / —
not
necessary
49 * pulse width for motor control 0 - 3 1 / 2 1 - 4
50 * Rule variant 0 - 3 2 / 3 1 - 4
51 *
Bit0:motorpolarityreversal
Bit1:lightingpolarityreversal
Bit2:trackpolarityreversal
0 / 1
0 / 2
0 / 4
***
0 - 7
0 / 4
not necessary
* Changes done under Selectrix will automatically be carried out under DCC and vice versa.
*** The values for the desired settings must be added.