OPERATION & SERVICE MANUAL
Tronair, Inc. Phone: (419) 866-6301 | 800-426-6301
1740 Eber Rd Web: www.tronair.com
Holland, OH 43528-9794 Email: sales@tronair.com
Model: 02-0511C0132
5 Ton Two Stage Jack
03/2014 - Rev. 03

Questions and Answers

  • D
    David NovakAug 10, 2025
    Why does my Tronair 02-0511C0132 fail to lift the rated load?
    • E
      Erika ParkerAug 10, 2025
      There are several reasons why your Tronair Jacks might fail to lift the rated load. It could be due to the release valve not being closed properly; ensure it is fully tightened. The fluid level might be low; refill to the correct level. The pressure relief valve could be improperly adjusted; adjust or replace it. There might be leakage at the inlet or outlet check ball; inspect the valve body for wear or replace the valve body and check balls. Also, make sure the vent screw is open.
  • B
    Brent ChungAug 14, 2025
    What to do if Tronair 02-0511C0132 Jacks rams will not support load?
    • D
      dcaseAug 15, 2025
      If the rams on your Tronair Jacks won't support the load after manual or pneumatic pump up, it could be due to a few reasons. First, check for external leakage from the ram o-ring seals; if present, replace the defective seal and back up ring. Additionally, a leaking pressure check valve or a leaking pressure relief valve could be the cause; inspect the valve body for wear or replace the valve body and check balls. For the pressure relief valve, remove it and inspect the ball and ball seat in the pump block, replacing any defective parts.
  • T
    Thomas BradleyAug 19, 2025
    How to fix Tronair 02-0511C0132 when it fails to lower?
    • R
      ramirezkellyAug 20, 2025
      If your Tronair Jacks fail to lower, there are a few things you can check: * Ensure the ram locknut is loosened by raising the jack ¼ inch and releasing the locknut. * Verify the vent screw is open. * Inspect the O-ring for pinching or rolling, and replace the o-ring and back-up ring, cleaning up any debris from the cylinder wall.
  • S
    Suzanne ParsonsAug 25, 2025
    Why do Tronair Jacks rams raise and fall with each manual pump stroke?
    • H
      hayesrobertAug 26, 2025
      If the rams on your Tronair Jacks raise and fall with each manual pump stroke, the issue might stem from a few potential causes. It could be that the release valve is open; ensure you fully tighten it. Alternatively, the inlet check valve or the pressure check valve might not be seated or could be sticking; try pumping rapidly to dislodge any obstructions or consider replacing the valve body.
  • D
    Dr. Brian HernandezAug 30, 2025
    How to fix external fluid leakage at rams on Tronair Jacks?
    • C
      Cassandra KimAug 30, 2025
      To fix external fluid leakage at the rams on your Tronair Jacks, remove the rams as a unit from the cylinder and inspect the parts. The leakage may be caused by a damaged o-ring, backup ring, or inner cylinder wall. Replace the o-ring and any other defective parts.
  • T
    tbarnesSep 4, 2025
    How to stop fluid leakage at pump piston on Tronair Jacks?
    • J
      Joshua MccoySep 5, 2025
      To address fluid leakage at the pump piston or pump body of your Tronair Jacks, remove the piston and pump body. Inspect for damage to the backup ring, o-ring, piston, or pump body. Replace any defective parts, and be sure to replace the removed o-ring and backup ring.