OPERATION & SERVICE MANUAL
Tronair, Inc. Phone: (419) 866-6301 | 800-426-6301
1 Air Cargo Pkwy East Web: www.tronair.com
Swanton, OH 43558 Email: sales@tronair.com
12 Ton (10.8 Metric Ton)
Axle Jack
Models:
02-7833C0110, 02-7846C0110,02-7852C0100,
02-7861C0100, 02-7861-9100, 02-7863C0100,
02-7902C0100, 02-7918C0100, 02-7918C9100
05/2021 Rev. 03

Questions and Answers

  • L
    Lisa RogersAug 10, 2025
    Why do my Tronair Jacks fail to lift the rated load?
    • S
      Suzanne PetersonAug 10, 2025
      If your Tronair Jacks fail to lift the rated load, several factors could be at play. Ensure the release valve is fully tightened and that the fluid level is correct. The pressure relief valve may need adjustment or replacement. Check for leakage at the inlet or outlet check ball, inspecting the valve body for wear. Lastly, make sure the vent screw is open.
  • R
    Robert ThomasAug 15, 2025
    What to do if ram(s) raise and fall with each manual pump stroke on Tronair 02-7833C0110?
    • J
      Joe KingAug 15, 2025
      If the rams on your Tronair Jacks raise and fall with each manual pump stroke, the issue could stem from a few causes. First, ensure the release valve is fully tightened. If that's not the problem, the inlet check valve or the pressure check valve might not be seated correctly or could be sticking. Try pumping rapidly to dislodge any obstructions, or consider replacing the valve body.
  • L
    Lori BakerAug 20, 2025
    Why Tronair 02-7833C0110 ram(s) will not support load after manual or pneumatic pump up?
    • F
      Frederick WardAug 20, 2025
      If the rams on your Tronair Jacks will not support the load after manual or pneumatic pump up, it could be due to leaking ram o-ring seals. Check for external leakage and if present, replace the defective seal and back up ring. Alternatively, it could be caused by a leaking pressure check valve or a leaking pressure relief valve. For the pressure check valve, inspect the valve body for wear or replace the valve body and check balls. For the pressure relief valve, remove the release valve and inspect the ball and ball seat in the pump block, replacing any defective parts.
  • T
    Taylor SmithAug 26, 2025
    How to fix Tronair 02-7833C0110 Jacks that fails to lower?
    • M
      morganmyersAug 26, 2025
      If your Tronair Jacks fail to lower, there are a few potential reasons. First, make sure the ram locknut is loosened by raising the jack ¼ inch and then releasing the locknut. Also, ensure the vent screw is open. Finally, check the O-ring for pinching or rolling; if damaged, replace the o-ring and back-up ring, and clean up any debris from the cylinder wall.
  • V
    Victoria HallAug 30, 2025
    How to stop external fluid leakage at ram(s) on Tronair Jacks?
    • A
      Amy CampbellAug 30, 2025
      If you notice external fluid leakage at the rams of your Tronair Jacks, it may be due to a damaged o-ring, backup ring, or inner cylinder wall. Remove the ram(s) as a unit from the cylinder and inspect the parts. Replace the o-ring and any other defective parts.
  • M
    mhendersonSep 4, 2025
    What causes fluid leakage at pump piston or pump body in Tronair 02-7833C0110 Jacks?
    • M
      mckayjamesSep 4, 2025
      If you observe fluid leakage at the pump piston or pump body of your Tronair Jacks, it could be due to a damaged backup ring, o-ring, piston, or pump body. Remove the piston and pump body to inspect for damage. Replace any defective parts, and be sure to replace the removed o-ring and backup ring.