EasyManua.ls Logo

Tronair 02-7854C0110 - User Manual

Tronair 02-7854C0110
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
OPERATION & SERVICE MANUAL
Tronair, Inc. Phone: (419) 866-6301 | 800-426-6301
1 Air Cargo Pkwy East Web: www.tronair.com
Swanton, OH 43558 Email: sales@tronair.com
Model: 02-7854C0110
12 Ton (10.87Metric Ton) and
25 Ton (22.68 Metric Ton)
Axle Jack
03/2008 - Rev. 02

Questions and Answers

  • S
    Sara CooperAug 3, 2025
    Why do my Tronair Jacks fail to lift the rated load?
    • B
      Beth LeeAug 3, 2025
      If your Tronair Jacks fail to lift the rated load, several factors could be at play. Ensure the release valve is fully tightened and that the fluid level is correct. The pressure relief valve may need adjustment or replacement. Check for leakage at the inlet or outlet check ball, inspecting the valve body for wear. Lastly, make sure the vent screw is open.
  • W
    wrightbillyAug 8, 2025
    What to do if ram(s) raise and fall with each manual pump stroke on Tronair 02-7854C0110?
    • W
      William MolinaAug 8, 2025
      If the rams on your Tronair Jacks raise and fall with each manual pump stroke, the issue could stem from a few causes. First, ensure the release valve is fully tightened. If that's not the problem, the inlet check valve or the pressure check valve might not be seated correctly or could be sticking. Try pumping rapidly to dislodge any obstructions, or consider replacing the valve body.
  • E
    earl60Aug 13, 2025
    Why Tronair Jacks ram(s) will not support load after manual or pneumatic pump up?
    • D
      Daniel BoydAug 13, 2025
      If the rams on your Tronair Jacks will not support the load after manual or pneumatic pump up, it could be due to leaking ram o-ring seals. Check for external leakage and if present, replace the defective seal and back up ring. Alternatively, it could be caused by a leaking pressure check valve or a leaking pressure relief valve. For the pressure check valve, inspect the valve body for wear or replace the valve body and check balls. For the pressure relief valve, remove the release valve and inspect the ball and ball seat in the pump block, replacing any defective parts.
  • H
    hammondlaurenAug 18, 2025
    How to fix Tronair 02-7854C0110 Jacks that fails to lower?
    • J
      James CarpenterAug 18, 2025
      If your Tronair Jacks fail to lower, there are a few potential reasons. First, make sure the ram locknut is loosened by raising the jack ¼ inch and then releasing the locknut. Also, ensure the vent screw is open. Finally, check the O-ring for pinching or rolling; if damaged, replace the o-ring and back-up ring, and clean up any debris from the cylinder wall.
  • A
    Anthony TravisAug 25, 2025
    How to stop external fluid leakage at ram(s) on Tronair Jacks?
    • M
      Maria KelleyAug 25, 2025
      If you notice external fluid leakage at the rams of your Tronair Jacks, it may be due to a damaged o-ring, backup ring, or inner cylinder wall. Remove the ram(s) as a unit from the cylinder and inspect the parts. Replace the o-ring and any other defective parts.
  • D
    David Jackson DVMAug 28, 2025
    What causes fluid leakage at pump piston or pump body in Tronair Jacks?
    • J
      Julie LivingstonAug 28, 2025
      If you observe fluid leakage at the pump piston or pump body of your Tronair Jacks, it could be due to a damaged backup ring, o-ring, piston, or pump body. Remove the piston and pump body to inspect for damage. Replace any defective parts, and be sure to replace the removed o-ring and backup ring.

Summary

Operating Instructions

Jack Instructions

Procedures for raising nose and main aircraft gears, including placement and extension adjustments.

Maintenance

Servicing Jack

Detailed steps for disassembling and re-assembling the hydraulic jack components.

Jack Function Load Test

Procedure for testing jack capacity and function, ensuring safety precautions are followed.

Trouble Shooting

Parts List

APPENDIX I Enerpac Instructions & Repair Parts

Safety Issues

Read and follow all safety precautions to avoid personal injury or property damage during system operation.

Installation

Instructions for connecting pumps, installing pressure gauges, and connecting hoses to cylinders or tools.

Air Removal

Steps to remove air from the hydraulic system for single and double-acting cylinders to ensure smooth operation.

Trouble Shooting Guide

A guide to diagnose and resolve common problems encountered with hydraulic pumps and cylinders.

APPENDIX II Safety Data Sheet MIL-PRF-5606 Hydraulic Fluid

Hazards Identification

Material classification and labeling according to regulatory guidelines, including hazard and precautionary statements.

Fire Fighting Measures

Information on appropriate extinguishing media, fire-fighting instructions, and potential fire hazards.

Exposure Controls; Personal Protection

Details on exposure limits, engineering controls, and recommended personal protective equipment.

Transport Information

Classification and regulations for transporting the material via land, sea, and air.

APPENDIX IV Maintenance Schedule

Maintenance Schedule

Recommended preventative maintenance procedures for axle jacks, including 90-day inspections and annual load tests.

Tronair 02-7854C0110 Specifications

General IconGeneral
BrandTronair
Model02-7854C0110
CategoryJacks
LanguageEnglish