EN 10
Operating manual – laser distance measuring device BD16
Fault indications
The following fault indications can appear in the lower
measurement value display together with the word INFO:
Display Cause Remedy
101 The reception of the
reflected signal is too
weak.
Repeat measurement on another
surface with better reflective
properties or use a target plate.
102 The reception of the
reflected signal is too
strong.
201 The ambient light is too
intense.
Change the ambient light conditions
for the measurement.
203 The batteries are almost
empty.
Change the batteries, see chapter
Battery change.
301 The temperature is too
high.
Allow the device to cool down.
Observe the permissible operating
temperature according to the
Technical data chapter.
302 The temperature is too
low.
Allow the device to warm up. Observe
the permissible operating temperature
according to the Technical data
chapter.
401 Hardware fault Repeatedly switch the device on and
off. If the symbol does not disappear,
please contact your retailer.
402 Calculation error Repeat the measurement. Pay
attention to the measurement
sequence and position of the device.
Maintenance and repair
Battery change
A battery change is required when the error message INFO101
appears on the display or when the device can no longer be
switched on (see chapter Inserting the batteries).
Before changing the batteries, remove the belt clip if it is
mounted.
A.
B.

Other manuals for Trotec BD16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trotec BD16 and is the answer not in the manual?

Trotec BD16 Specifications

General IconGeneral
BrandTrotec
ModelBD16
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals