EN 6
Operating manual – air cooler PAE 50
Mounting the feet
If you want to position and operate the device on a slope, first
mount the feet.
1. Place the device on its side and position the feet.
2. Fasten each foot on the device with one screw.
Filling the water tank
The device requires fresh drinking water for air cooling.
Note
Fill the device with fresh drinking water only. The
water temperature must not exceed 40°C.
Info
If possible, change the water on a daily basis to
prevent bacterial growth.
Observe the following when using the ice packs:
• Put the ice packs into a freezer for at least 4hours before
use.
• The water tank(11) should be filled with water before
inserting the ice packs.
Info
When using ice packs at high outside temperatures,
condensation may form at the water tank and drip onto
the floor.
1. Disconnect the device from the mains before refilling water
or putting ice packs into the device.
2. Open the water funnel(3).
3. Ensure tight fit of the rubber stopper(10), for otherwise
there might be uncontrollable water leakage.