EasyManua.ls Logo

Trotec PAE 50 - Filter Installation and Airflow Adjustment

Trotec PAE 50
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 EN
Operating manual – air cooler PAE 50
4. Fill the water tank(11) with fresh drinking water only.
Optionally, you can add ice cubes made of drinking water
for additional cooling.
ð Observe the minimum and maximum filling level at the
filling level indicator.
The water tank must be filled up to minimum filling level
to enable pump operation.
5. If required, put the ice packs into the water tank(11) for
additional cooling. The ice packs can be inserted in two
ways.
ð Version 1: Insert the ice packs into the device through
the water funnel.
ð Version 2: Remove the honeycomb filter(5) and the air
filter(9) at the rear of the device and insert the ice
packs.
6. Close the flap of the water funnel(3) or reinsert the
honeycomb filter(5) and the air filter(9).
7. Make sure that the device is neither damp nor wet on the
outside. Otherwise wipe it dry.
Inserting honeycomb filter and air filter
Note
When set to air cooling mode, the device should not be
operated without the honeycomb filter, otherwise
cooling will not work.
Note
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
• Make sure that both the honeycomb and the air filter are
installed before switching the device on.
Adjusting the ventilation flaps
• Prior to switching the device on, adjust the ventilation flaps
at the air outlet.