EN 15
dehumidifier TTR 57 E
3. Allow the filter to dry completely. Do not insert a wet filter
into the device!
4. Reinsert the air filter into the device.
Emptying the condensation tank
When the condensation tank(5) is full or not inserted correctly,
the device stops dehumidification operation and switches itself
off. The Tank Full LED(22) lights up and an acoustic signal is
emitted.
1. Take the condensation tank(5) out of the device.
2. Empty the condensation tank(5) over a drain or sink.
3. Rinse the condensation tank(5) with clear water. Regularly
clean the condensation tank(5) using a mild cleaning
agent (no dish detergent!).
4. Refit the condensation tank(5) into the device. Make sure
not to damage the float when inserting or removing the
condensation tank(5).
ð In doing so, make sure that the float is positioned
correctly.
ð In doing so, make sure that the condensation tank(5) is
inserted correctly, for otherwise the device cannot be
switched back on.
Activities required after maintenance
If you want to continue using the device:
• Leave the device to rest for one hour before switching it
back on. Otherwise the device could be damaged and no
longer work properly. Any warranty claims will be voided in
this case.
• Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
• Store the device according to the Storage chapter.