Do you have a question about the Truma BG 10 and is the answer not in the manual?
Power Output | 10 kW |
---|---|
Fuel Type | Gas |
Gas Type | Propane / Butane |
Operating Pressure | 30 mbar |
Gas Consumption | 0.78 kg/h |
Water Capacity | 10 liters |
Water Pressure | 1.5 bar |
Type | Gas Boiler |
The appliance is approved for installation and operation in caravans, motor homes, and mobile homes.
Other uses are prohibited, including in buses, commercial vehicles, boats, huts, and awnings.
Read and observe operating instructions carefully to prevent material damage and risk to life.
Use upright gas cylinders and gas phase. Liquid phase usage will damage the system.
Avoid ignition sources, open windows, evacuate, shut off gas. Have system inspected.
Do not operate during refuelling. Switch off appliance and gas supply.
Hot water can cause burns. Check water temperature before use.
Keep flammable materials away from the appliance and installation compartment.
Appliance, gas system, and exhaust duct require expert inspection every two years.
A safety shut-off device is required for driving to prevent uncontrolled gas escape.
Drain the boiler if there is a risk of frost to prevent damage and voiding warranty.
Use a pressure reducer for central supply or powerful pumps to limit pressure to 2.8 bar.
Fit the cowl cover securely before travelling and ensure it is locked.
Rinse water supply with warm, clear water before first use. Affix warning sticker.
Ensure drain valve is closed. Open hot tap, switch on pump, and let water displace air.
Ensure boiler is not empty. Remove cowl cover. Open gas cylinder/valve. Turn on via control panel.
For BGE 10 model only. Never operate empty. Switch on via control panel at 850 W or 1300 W.
Red LED indicates a fault. Clear by switching off, waiting 5 mins, then switching on.
Switch off at control panel. Fit cowl cover. Drain if frost risk. Close gas supply if unused.
Drain boiler during frosty periods. Turn on hot taps, open drain valve (lever vertical).
12 V fuse on electronic control unit. Replace with same type: 1.6 A (slow-acting).
System pressure max. 4.5 bar. Gas type: Liquid gas. Operating pressure: 30 mbar.
Nominal heat load 1.5 kW. Heating time 15°C to 70°C: ~31 min (gas), ~29 min (electric).
12 V consumption: Ignition 0.16 A, Heating 0.12 A. 230 V consumption: 850 W or 1300 W.
Covers boiler not operating, red LED on, or 'Fault' status. Check power, gas, pressure, air.
Covers boiler not operating or overtemperature sensor in electric mode. Check power and water.
Addresses dripping drain valve or warm water into cold supply. Check pressure, fit non-return valve.
Covers material/manufacturing defects for 24 months for Consumers in EU states, Iceland, Norway, Switzerland, Turkey.
Excludes improper use, installation, non-authorised repairs, wear, non-original parts, chemical damage, modifications.
Claim with an authorised service partner or Truma Service Centre. Provide defect details, serial number, and purchase date.