8
Technical data
determined in accordance with EN 624 or Truma test
conditions
Type of gas
LPG (Liquefied Petroleum Gas – propane / butane)
Operating pressure
2.75kPa (see type plate)
Water capacity
10 litres
Heating up time from approx. 15 °C to approx. 60 °C
Hot water system approx. 23 minutes
(measured according to EN 15033)
Heater + hot water system approx. 90 min.
Pump pressure
max. 0.28 MPa
System pressure
max. 0.45 MPa
Nominal input (Propane)
Combi 2 E CP plus (Australia): 6.9MJ/h
Combi 4 E CP plus (Australia): 13.6MJ/h
Thermal output
Electrical operation (240V): 980W/1960 W
Mixed operation (gas and electrical): max. 3900W
Gas operation
Combi 2 E CP plus (Australia): max. 1950W
Combi 4 E CP plus (Australia): max. 3900W
Gas consumption (Propane)
Combi 2 E CP plus (Australia): 130 g/h
Combi 4 E CP plus (Australia): 130 – 260 g/h
Air delivery volume (free-blowing without hot-air pipe)
with 3 hot-air outlets max. 249 m³/h
with 4 hot-air outlets max. 287 m³/h
Current input at 12 V
Heater + hot water system
Short-term max. 5.6 A (average power consumption 1.1 A)
Heating up of hot water system: 0.4 A
Stand-by: 0.001 A
Current input at 240 V
4.1 A (980 W) or 8.1 A (1960 W)
Weight (not containing water)
Heater unit: 15.8 kg
Heater unit with peripheral devices: 16.4 kg
Declaration of conformity
The heater Combi 2 E / 4 E CP plus (Australia) is approved
according AS4552, AS4556, AS/NZS 60335.2.21+A1-A3,
AS/NZS 60335.2.30+A1, AS/NZS 60335.1+A1 and fulfills
these standards:
Dimensions
Fig. 8
The right to make technical modifications is reserved!
Accessories
Truma CP plus
Digital control panel Truma CP plus (part no. 36020-01).
Fig. 9
Accessories (without picture) for control panels
– Cable 3 m (part no. 36110-01)
– Cable 6 m (part no. 36110-02)
– Cable 9 m (part no. 36110-03)