7
Maintenance
Only original Truma parts may be used for maintenance and
repair work.
– Even outside the season, the heater should be operated
once a month for about ten minutes.
– Clean installation area at least once per year, and have unit
checked for soiling and cleaned by an expert if necessary.
– The drain valve must be actuated regularly (at least twice
per year) in order to remove limescale deposits and to ensu-
re that it is not blocked.
Biofilm, deposits and limescale must be removed using
chemicals to protect the unit from infestation by microorgan-
isms. Only chloride-free products must be used in order to
prevent damage to the unit.
The effectiveness of the use of chemicals to combat microor-
ganisms in the unit can be increased by heating the water in
the hot water system to 70 °C at regular intervals.
– Set water temperature to 60 °C.
– Switch on unit.
Once the water in the water heater has reached a tem-
perature of 60 °C, the burner will switch off. The unit
must stay switched on for at least 30 minutes and no warm
water may be withdrawn. The residual heat in the heat ex-
changer will heat the water up to 70 °C.
Fuses
The fuses are located in the electronic control unit, beneath
the connector cover. When replacing a fuse, be sure to use
the same type.
Device fuse: 10 A – slow – 5 x 20 mm (T 10 A)
Burner fuse: 20 A – slow – 6.3 x 32 mm
T 20 A
T 10 A
Fig. 5
Disposal
The heater unit must be disposed of in accordance with the
administrative regulations of the country in which it is in use.
National regulations and laws must be observed.
Technical data
(found by Truma Test conditions)
Protection type / protection class
IP21 / class I
Fuel
Fuel, as per the Australian Fuel Standard (Automotive Diesel).
Operation with any form of biodiesel is not permitted.
Water volume
10 litres
Maximum working water pressure
500 kPa
P&T relief valve setting
500 kPa – 99 °C – 10 kW
Heating up time from approx. 15 °C to approx. 60 °C
Hot water system approx. 20 minutes (measured according to
EN 15033)
Heater + hot water system approx. 80 min.
Pump pressure
max. 280 kPa
System pressure
max. 450 kPa
Rated thermal output (automatic output levels)
2000 / 4000 / 6000 W
Fuel consumption
220 – 630 ml/h (110 ml/h during normal operation with
moderate heat output of 1000 W)
Air delivery volume (free-blowing without hot-air pipe)
max. 287 m³/h
Current input at 12 V
Heater + hot water system 1.8 – 7 A (in regular operation, be-
tween “Off” and “lowest operating level” less than 1.8 A).
Heating hot water system without operational heater, max.1.8 A
Stand-by: approx. 0.001 A
Weight (without water)
Heater unit: 16.2 kg
Heater unit with
peripheral devices: 17.6 kg
Water pressure reducer
Flow range water: 0 – 10 litres/min.
Maximum inlet pressure: 700 kPa
Maximum outlet pressure: 200 kPa
E1 122R 000232
E1 10R 035277
Dimensions
450 mm
525 mm
300 mm
Fig. 6
The right to make technical modifications is reserved!