Common Error Codes
#
Flashcode
Error
Action
149 lssl, slsl Overtemperature of the Water Temperature
Switch or Air Temperature Switch
Water Temperature Switch or
Air Temperature Switch out of
range sensor/harness,
excessive temperature
Allow system to cool
Go to Blue Pages:
Check WECO, Check
AECO
150 lssl, slls Overtemperature of the Air Temperature
Switch or Water Temperature Switch
Air Temperature Switch or
Water Temperature Switch out
of range sensor/harness,
excessive temperature
Allow system to cool
Go to Blue Pages:
Check AECO, Check
WECO
112 slll, ssss Combustion Failure: Flame not detected Flame was not detected during
ignition sequence potential
combustion issue (air, fuel,
spark)
1)
Check On/Off switch in
ON position 2) Check
supply gas pressure 3)
Check condition of
exhaust and intake -
properly installed, no
damage 4) Ensure
proper grounding and
incoming 12vdc 5) Allow
system to cool and
restart Go to blue
pages: 6) Check ignitor
7) check gas valve 8)
Check PCB
121 slll, lssl Combustion Failure: Flame unstable Flame unstable during
operation potential
combustion issue (air, fuel,
spark)
Same steps as #112
122 slll,lsls Combustion Failure: Flame not detected Flame was not detected during
ignition sequence potential
combustion issue (air, fuel,
spark)
Same steps as #112
202 llss, lsls Combustion Failure: Flame not detected Flame was not detected during
ignition sequence potential
combustion issue (air, fuel,
spark)
Same steps as #112
211 llsl, ssll Combustion Failure: Flame unstable Flame unstable during
operation potential
combustion issue (air, fuel,
spark)
Same steps as #112
212 llsl, slss Combustion Failure: Flame not detected Flame was not detected during
ignition sequence potential
combustion issue (air, fuel,
spark)
Same steps as #112
255 CP Plus Combi communication and/or
12VDC failure
Combi 12VDC supply power
inadequate or non-existent or
communication failure between
Combi and CP Plus
Verify 12VDC supply
voltage between 11-
15VDC, check CP Plus,
Data Cable, CP Plus 1A
Fuse

Other manuals for Truma Combi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Truma Combi and is the answer not in the manual?

Truma Combi Specifications

General IconGeneral
TypeCombination heater
FuelLPG
Water capacity10 liters
ControlDigital control panel
Safety FeaturesOverheat protection, flame monitoring
EfficiencyUp to 90%

Related product manuals