Fault Cause Rectification
Yellow LED flashes 2 x Overvoltage > 16.4 V Check battery voltage and voltage sources such as the
charger
(Only with Combi E) No 230 V operating voltage
230 V fuse defective
Overheating protection has been
triggered
Restore 230 V operating voltage
Replace 230 V fuse
Reset overheating protection, allow heating system to cool,
remove connection cover and press reset button
Yellow LED flashes 3 x Open window above cowl
(window switch)
Close window
Yellow LED flashes 4 x Warm air temperature and / or
water temperature exceeded:
Not all warm air ducts are
connected
Warm air outlets blocked
Circulated air intake blocked
Check whether the 4 warm air ducts are connected
Check individual outlet apertures
Remove blockage from circulated air intake
Summer mode with empty
water container
Fill boiler with water
Yellow LED flashes 5 x Room temperature sensor or
cable defective
Please contact Truma Service
Yellow LED flashes 6 x Water temperature exceeded in
summer mode
Fill boiler with water
Yellow LED flashes 7 x Control panel or control panel
cable defective
Please contact Truma Service
Yellow LED flashes 8 x FrostControl heating element
has a short circuit
Disconnect heating element plug from electronic control unit,
replace heating element
If these actions do not remedy the problem, please contact Truma Service.