EasyManua.ls Logo

Truma DLE60CP - APPENDIX D - Electrical Connection Diagram

Truma DLE60CP
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
APPENDIX D – Electrical Connection Diagram
-t°-t°
-t°
Flame Rectification
Electrode - FRE
Flame Ignition
Electrode - FIE
Water Flow
Sensor - WFS
Power Switch
Internal Fuse
(10 A)
Power ON LED
Exhaust
Pressure
Switch - EPS
Water
Over Temperature
Switch - WOS
Exhaust
Over Temp.
Switch - EOS
Burner
Over Temp.
Switch - BOS
Circulation Line
Temperature
Sensor - WCT *
12 VDC
* only AquaGo™ Comfort and
AquaGo™ Comfort Plus
Safety Valve Modulator
Ground
Water Outlet
Temperature
Sensor - WOT
Water Inlet
Temperature
Sensor - WIT
MOT
Flue
Fan
If any of the original wire as supplied with the water heater
must be replaced, it must be replaced with wire 18 AWG (** 16 AWG) - 105 °C - UL1015, or its equivalent
18 AWG or 1 mm2 MWG (** 16 AWG or 1.5 mm2 MWG)
(green)
(green)
(grey)
(white)
( white)
(grey)
(blue)
(red)
(red)
( red)
(blue)
( blue)
(red **)
Gas Valve
Circulation
Pump*
(orange)
(yellow)
(brown)
(black)
(black)
(black)
(black)
(black **)
(orange)
(orange)
(brown)
(yellow)
(violet)
Error Code LED
Anti Freeze
Element *
(optional)
Control
Panel * /
Diagnosis
Fig. 35