DuoControl CSOperation
52 EN
50020-00980 ∙ 00 ∙ 08/2022

WARNING
Risk of fire and explosion hazard due to residual gases
Residual gases may escape and form a flammable gas mix-
ture with the air when the high-pressure hose is changed�

Do not use any naked flames or open fire�

Do not smoke�

WARNING
Risk of fire and explosion hazard due to damaged or
missing seal

Check the flat gasket during each high-pressure hose
change and replace it if it is ageing, hardening, cracking
or exhibits other visible defects�

Never use self-made seals; instead, only use Truma
original spare parts�

Ensure that the seal is available and properly installed�

It is advisable to replace the flat gasket G�13 (see chapter
„Accessories“) during each hose change�

Close the cylinder valve of the gas cylinder

Disconnect the high-pressure hose from the cylinder valve or clip-
on adapter� Observe the direction of rotation (left-hand thread)�

Loosen the high-pressure hose from the gas pressure regulator
or gas filter� Use the supplied screw aid (width across flat23mm)
for this purpose� Use a spanner (width across flat18mm) to hold
the gas pressure regulator in place�

Check the new high-pressure hose for contaminants� Clean the
high-pressure hose if necessary

Check the flat gasket for dirt or damage� Replace the flat gasket if
necessary

Insert the flat gasket accurately into the hose connection�

Screw the new high-pressure hose onto the gas pressure
regulator or gas filter� Use the supplied screw aid (width across
flat23mm) for this purpose� Use a spanner (width across

Table of Contents