EasyManuals Logo

Truma FrostControl Operating Instructions

Truma FrostControl
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
11
Trouble-shooting list
Fault Cause Rectification
The drain valve (FrostControl)
opens.
Temperature at drain valve less
than approx. 3 °C. (If the tem-
perature is below approximately
3 °C, the drain valve will open
automatically!)
If necessary, switch on the vehicle heating unit.
It can be closed again at temperatures above
approx. 7 °C on the drain valve!
The drain valve (FrostControl)
can no longer be closed.
Temperature at drain valve is below
approximately 7 °C.
Rotary switch is not at “Operation”.
If necessary, switch on the vehicle heating unit.
It can be closed again at temperatures above
approx. 7 °C on the drain valve!
Turn the drain valve’s rotary switch to “Operation”,
then press the push button until it engages.
Water flows intermittently from
the FrostControl drain muff.
Water pressure too high. Check pump pressure (max. 2.8 bar). If con-
nected to a central water supply (rural or urban
connection), a pressure reducer must be used,
which will prevent pressures higher than 2.8 bar
entering the boiler.
If these measures do not remove the failure, please contact the Truma Service Centre.

Other manuals for Truma FrostControl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Truma FrostControl and is the answer not in the manual?

Truma FrostControl Specifications

General IconGeneral
MaterialPlastic
Protection classIP 44
TypeFrostControl
ActivationAutomatic opening at low temperatures
Operating voltage12 V
WeightApprox. 110 g

Related product manuals