  • H
    Heidi FosterAug 16, 2025
    Why is my Truper Air Compressor pumping oil?
    • J
      Joseph Baker DDSAug 16, 2025
      If your Truper Air Compressor is pumping oil, it might be due to several reasons. First, the admission filter could be blocked, in which case you should clean or replace it. Second, the oil viscosity might be too low, so you should change the oil to the correct type. Third, the oil level might be too high, so remove the excessive oil from the casing. Other possible causes are broken or not settled piston rings, or cylinders or pistons with scratches, wear or streaks. In these cases you should go to your nearest TASC*.
  • A
    Alexis CarsonAug 22, 2025
    Why is the air feed reduced in my Truper Air Compressor?
    • C
      Cheyenne EverettAug 22, 2025
      If your Truper Air Compressor has reduced air feed, the admission filter might be clogged, so clean or replace the filter. There might be air leaks in piping, so look for air leaks and use sealing tape in all the leaky connections. Other possible causes are leaky, broken, carbonized or loose valves or restricted air ducts, worn or scratched rod bearings, defective bearing in the crank or in the motor shaft, loose motor fan, or the transmission band has too much play. In these cases you should go to your nearest TASC*.
  • T
    Terry RasmussenAug 25, 2025
    What to do if my Truper Air Compressor is starting and stopping too often?
    • S
      schwartzcodyAug 26, 2025
      If your Truper Air Compressor is experiencing excessive starting and stopping, it may be necessary to drain the tank by opening the valve on the lower side of the tank. Also, inspect for air leaks in the pipeline and use sealing tape on any leaky connections. If there are leaks in the tank security valve, inspect to detect leaks and if changing the valve is necessary go to a TASC*.
  • G
    gregory42Aug 27, 2025
    What to do if my Truper Air Compressor is not reaching its speed?
    • A
      Andrew RogersAug 27, 2025
      If your Truper Air Compressor is not reaching its normal speed, double-check the feeding line voltage, the fuses, or correct the motor overload, as voltage drops in the feeding line might be the cause. Alternatively, consult with a qualified electrician if there's energy deficient regulation (unbalanced line). If a fault in the check valve is the cause, inspect to detect leaks and if replacing the valve is necessary go to a TASC*.
  • S
    Sherry AlvarezAug 30, 2025
    Why is my Truper Air Compressor running so hot?
    • A
      Allison ColeAug 30, 2025
      If your Truper Air Compressor is running excessively hot, it could be due to several reasons. There is a possibility the flywheel is blocked, leaks in the tank safety valve, the oil level is too low, leaky, broken, carbonized or loose valves or restricted air ducts, or wrong rotation direction. In these cases you should go to the nearest TASC*. If the oil level is too low, add oil in the casing up to the right level.
  • M
    Mrs. Debra Anderson DDSSep 2, 2025
    What to do if my Truper Air Compressor motor is not running?
    • M
      Mr. Gordon Jordan DDSSep 2, 2025
      If your Truper Air Compressor motor is not running, double-check the feeding line voltage, the fuses, or correct the motor overload, as voltage drops in the feeding line might be the cause. Alternatively, consult with a qualified electrician if there's energy deficient regulation (unbalanced line). If the capacitor is faulty or damaged, ask for a motor capacitor check-up (only monophasic units) in a TASC*. Double-check if the tank pressure is higher than the cutting pressure in the pressure switch (the motor will start again when pressure in the tank drops below the cutting pressure). Check for leaks in the check valve and if replacing the valve is needed go to a TASC*. Verify if motor overload has been triggered and press the thermic button to restart the motor.
  • J
    John CookSep 4, 2025
    Why is my Truper Air Compressor making banging and rattling noises?
    • P
      Patricia BakerSep 4, 2025
      If you hear banging and rattling sounds from your Truper Air Compressor, it may be due to several reasons. Loose pulley or excessive axial backlash in the motor shaft, coal in the upper side of the piston, leaky, broken, carbonized or loose valves or restricted air ducts, worn or scratched rod bearings, defective bearing in the crank or in the motor shaft, loose motor fan, cylinders or pistons with scratches, worn or with lines, or the transmission band has too much play. For service and repairs go to your nearest TASC*.
  • K
    Kenneth EsparzaSep 7, 2025
    Why are the lights blinking when my Truper Air Compressor is running?
    • B
      Brian CopelandSep 7, 2025
      If the lights are blinking when your Truper Air Compressor is operating, double-check the feeding line voltage, the fuses, or correct the motor overload, as voltage drops in the feeding line might be the cause. Alternatively, consult with a qualified electrician if there's energy deficient regulation (unbalanced line).
  • I
    Ian BonillaSep 10, 2025
    What causes abnormal piston wear in my Truper Air Compressor?
    • L
      Lauren Castillo DDSSep 10, 2025
      Abnormal piston, worn ring or cylinder in your Truper Air Compressor can be caused by several factors. If the oil viscosity is too low, change and use the right type of oil. If the oil level is too low, add oil to the casing up to the right level. If the atmosphere is dusty, a more effective filter is needed in the air admission.
  • E
    Evan OrtegaSep 12, 2025
    What causes oxidation in the cylinders of my Truper Air Compressor?
    • D
      Dominique PetersonSep 13, 2025
      If there is oxidation in the cylinders of your Truper Air Compressor, it could be because the wrong type of oil is being used, so change and use the right type of oil. It could also be that the compressor has been operating in a damp place for a long period of time, in which case you should go to your nearest TASC*.